Literature DB >> 26409830

Quantification of intra-fraction changes during radiotherapy of cervical cancer assessed with pre- and post-fraction Cone Beam CT scans.

Sabrina T Heijkoop1, Thomas R Langerak2, Sandra Quint2, Jan Willem M Mens2, Andras G Zolnay2, Ben J M Heijmen2, Mischa S Hoogeman2.   

Abstract

BACKGROUND AND
PURPOSE: With the introduction of Intensity Modulated Radiotherapy (IMRT) and image-guided plan-of-the-day strategies, the treatment of cervical cancer has become more sensitive to intra-fraction uncertainties. In this study we quantified intra-fraction changes in cervix-uterus shape, bladder and rectum filling, and patient setup using pre- and post-fraction CBCT scans.
MATERIALS AND METHODS: A total of 632 CBCT scans were analyzed for 16 patients with large tip-of-uterus displacement (>2.5 cm) measured in an empty and full bladder CT scan. In all scans, the bladder, cervix-uterus, and rectum were delineated. For rectum and bladder, intra-fraction volume changes were assessed. Systematic cervix-uterus intra-fraction displacements were obtained by non-rigidly aligning the pre-fraction cervix-uterus to that in the post-fraction CBCT. Intra-fraction patient setup changes were obtained by rigidly aligning pre- and post-CBCTs using the bony anatomy.
RESULTS: The mean time between pre- and post-fraction CBCT scan was 20.8 min. The group-mean intra-fraction displacements averaged over the cervix-uterus were 0.1±1.4/1.8±1.5/-2.8±1.8 (LR/CC/AP) mm. The group-mean 5th and 95th percentile intra-fraction displacements were -2.3,2.1/-0.8,4.9/-5.8,0.5 (LR/CC/AP) mm. There was a significant correlation between bladder inflow rate and cervix-uterus motion (r=0.6 and p<0.01). Intra-fraction changes in patient setup were 1.3/0.4/0.6 and 1.4/1.0/1.1 mm (LR/CC/AP), for systematic and random changes, respectively.
CONCLUSION: Intra-fraction cervix-uterus motion can be considerable and should be taken into account using appropriate PTV margins.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  IMRT; Intra-fraction motion; Locally advanced cervical cancer; Online adaptive radiotherapy; Plan-of-the-day; VMAT

Mesh:

Year:  2015        PMID: 26409830     DOI: 10.1016/j.radonc.2015.08.034

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Weekly Cisplatin and Volumetric-Modulated Arc Therapy With Simultaneous Integrated Boost for Radical Treatment of Advanced Cervical Cancer in Elderly Patients: Feasibility and Clinical Preliminary Results.

Authors:  Rosario Mazzola; Francesco Ricchetti; Alba Fiorentino; Niccolò Giaj Levra; Sergio Fersino; Gioacchino Di Paola; Ruggero Ruggieri; Filippo Alongi
Journal:  Technol Cancer Res Treat       Date:  2016-07-08

2.  Prospective Validation of a High Dimensional Shape Model for Organ Motion in Intact Cervical Cancer.

Authors:  Casey W Williamson; Garrett Green; Sonal S Noticewala; Nan Li; Hanjie Shen; Florin Vaida; Loren K Mell
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-08-22       Impact factor: 7.038

3.  Treatment Outcome of the Combination Therapy of High-dose rate Intracavitary Brachytherapy and Intensity-modulated Radiation Therapy With Central-shielding for Cervical Cancer.

Authors:  Yuki Mukai; Yumiko Minagawa; Hiromi Inoue; Akiko Sato; Kengo Matsui; Takanori Fukuda; Kazuya Onuma; Hideyuki Hongo; Ryosuke Shirata; Hironori Nagata; Harumitu Hashimoto; Tomio Inoue; Masaharu Hata; Motoko Omura
Journal:  In Vivo       Date:  2020 Nov-Dec       Impact factor: 2.155

4.  Human-level comparable control volume mapping with a deep unsupervised-learning model for image-guided radiation therapy.

Authors:  Xiaokun Liang; Maxime Bassenne; Dimitre H Hristov; Md Tauhidul Islam; Wei Zhao; Mengyu Jia; Zhicheng Zhang; Michael Gensheimer; Beth Beadle; Quynh Le; Lei Xing
Journal:  Comput Biol Med       Date:  2021-12-17       Impact factor: 4.589

5.  A parameterized model for mean urinary inflow rate and its preliminary application in radiotherapy for cervical cancer.

Authors:  Fu Jin; Huan-Li Luo; Juan Zhou; Ding-Yi Yang; Li Yin; Xiao-Qing Yang; Ya-Nan He; Xian-Feng Liu; Da Qiu; Ming-Song Zhong; Han Yang; Chao Li; Qi-Cheng Li; Guang-Lei He; Ying Wang
Journal:  Sci Rep       Date:  2017-03-21       Impact factor: 4.379

6.  Comparison of survival, acute toxicities, and dose-volume parameters between intensity-modulated radiotherapy with or without internal target volume delineation method and three-dimensional conformal radiotherapy in cervical cancer patients: A retrospective and propensity score-matched analysis.

Authors:  Yu-Qin Liang; Sen-Quan Feng; Wen-Jia Xie; Qiong-Zhi Jiang; Yan-Fen Yang; Ren Luo; Elizabeth A Kidd; Tian-Tian Zhai; Liang-Xi Xie
Journal:  Cancer Med       Date:  2021-11-24       Impact factor: 4.452

7.  Analysis of EPID Transmission Fluence Maps Using Machine Learning Models and CNN for Identifying Position Errors in the Treatment of GO Patients.

Authors:  Guyu Dai; Xiangbin Zhang; Wenjie Liu; Zhibin Li; Guangyu Wang; Yaxin Liu; Qing Xiao; Lian Duan; Jing Li; Xinyu Song; Guangjun Li; Sen Bai
Journal:  Front Oncol       Date:  2021-09-14       Impact factor: 6.244

8.  Role of deformable image registration for delivered dose accumulation of adaptive external beam radiation therapy and brachytherapy in cervical cancer.

Authors:  Laura E van Heerden; Jorrit Visser; Kees Koedooder; Coen Rn Rasch; Bradley R Pieters; Arjan Bel
Journal:  J Contemp Brachytherapy       Date:  2018-12-28

9.  Early clinical experience with varian halcyon V2 linear accelerator: Dual-isocenter IMRT planning and delivery with portal dosimetry for gynecological cancer treatments.

Authors:  Hayeon Kim; M Saiful Huq; Ron Lalonde; Christopher J Houser; Sushil Beriwal; Dwight E Heron
Journal:  J Appl Clin Med Phys       Date:  2019-10-29       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.