Literature DB >> 26408623

[Value of single photon emission computed tomography/computerized tomography in the diagnosis of hyperparathyroidism and the comparative study with multiple imaging modality].

Min Zhao1, Xinhui Li2, Jin Huang2, Xiaoqin Yin2.   

Abstract

OBJECTIVE: To compare the diagnostic value among the single photon emission computed tomography/computerized tomography (SPECT/CT), (99m)Tc-sestamibi (MIBI) planar scintigraphy, ultrasonography (US) and computerized tomography (CT) in diagnosis of patients with hyperparathyroidism (HPT).
METHODS: A total of 59 patients were retrospectively recruited for this study. The patients received parathyroidectomy and were verified by pathological examination. Among them, 31, 28 and 26 patients received SPECT/CT, (99m)Tc-MIBI planar scintigraphy, US and CT, respectively, before the parathyroidectomy. The sensitivity for localization or qualitation was compared between SPECT/CT and (99m)Tc-MIBI planar scintigraphy; the sensitivity, specificity and accuracy were compared among the SPECT/CT, (99m)Tc-MIBI planar scintigraphy, US and CT.
RESULTS: There was no statistical difference in the sensitivity of localization between SPECT/CT and (99m)Tc-MIBI planar scintigraphy (P>0.05); however, the SPECT/CT exhibited more sensitive than the (99m)Tc-MIBI planar scintigraphy in detection of hyperplastic lesions (P<0.05). Among the four imaging modalities, SPECT/CT had advantages over (99m)Tc-MIBI planar scintigraphy in terms of accuracy (P<0.05). In contrast, the sensitivity of CT was not as good as that of SPECT/CT and US (both P<0.05). For the diagnosis of lesions with a diameter more than 1 cm, the sensitivity of SPECT/CT was the best (all P<0.05). However, the sensitivity of US was the best in diagnosis of lesions with a diameter less than 1 cm (all P<0.05).
CONCLUSION: The SPECT/CT is more effective than (99m)Tc-MIBI planar scintigraphy in diagnosis of HPT, especially in diagnosis of hyperplastic lesions. Both of SPECT/CT and US are recommended to localize the target parathyroid lesions of HPT before the parathyroidectomy.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26408623     DOI: 10.11817/j.issn.1672-7347.2015.09.012

Source DB:  PubMed          Journal:  Zhong Nan Da Xue Xue Bao Yi Xue Ban        ISSN: 1672-7347


  1 in total

1.  Diagnosis performance of 99mTc-MIBI and multimodality imaging for hyperparathyroidism.

Authors:  Jun Zhou; Di-Yu Lu; Liang Xia; Xiao-Jie Cheng
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-08-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.