Literature DB >> 26406019

Numerical analysis of the effect of side holes of a double J stent on flow rate and pattern.

Kyung-Wuk Kim1, Young Ho Choi2, Seung Bae Lee3, Yasutaka Baba4, Hyoung-Ho Kim1, Sang-Ho Suh1.   

Abstract

A double J stent has been used widely these days for patients with a ureteral stenosis or with renal stones and lithotripsy. The stent has multiple side holes in the shaft, which supply detours for urine flow. Even though medical companies produce various forms of double J stents that have different numbers and positions of side holes in the stent, the function of side holes in fluid dynamics has not been studied well. Here, the flow rate and pattern around the side holes of a double J stent were evaluated in curved models of a stented ureter based on the human anatomy and straight models for comparison. The total flow rate was higher in the stent with a greater number of side holes. The inflow and outflow to the stent through the side holes in the curved ureter was more active than in the straight ureter, which means the flow through side holes exists even in the ureter without ureteral stenosis or occlusion and even in the straight ureter. When the diameter of the ureter changed, the in-stent flow rate in the ureter did not change and the extraluminal flow rate was higher in the ureter with a greater diameter.

Entities:  

Keywords:  CFD; Ureter; flow; numerical analysis; stent

Mesh:

Year:  2015        PMID: 26406019     DOI: 10.3233/BME-151319

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  5 in total

1.  Freeze-casting porous chitosan ureteral stents for improved drainage.

Authors:  Kaiyang Yin; Prajan Divakar; Ulrike G K Wegst
Journal:  Acta Biomater       Date:  2018-11-07       Impact factor: 8.947

2.  Computational simulation of the flow dynamic field in a porous ureteric stent.

Authors:  Xiaohan Yang; Ali Mosayyebi; Dario Carugo
Journal:  Med Biol Eng Comput       Date:  2022-06-28       Impact factor: 3.079

Review 3.  Silicone vs. Polyurethane Stent: The Final Countdown.

Authors:  Suresh Mathias; Oliver Wiseman
Journal:  J Clin Med       Date:  2022-05-12       Impact factor: 4.964

4.  Failure of ureteral stents subject to extrinsic ureteral obstruction and stent occlusions.

Authors:  Tal Amitay-Rosen; Alon Nissan; Yaniv Shilo; Ishai Dror; Brian Berkowitz
Journal:  Int Urol Nephrol       Date:  2021-02-17       Impact factor: 2.370

5.  Analysis of Urine Flow in Three Different Ureter Models.

Authors:  Kyung-Wuk Kim; Young Ho Choi; Seung Bae Lee; Yasutaka Baba; Hyoung-Ho Kim; Sang-Ho Suh
Journal:  Comput Math Methods Med       Date:  2017-06-04       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.