Literature DB >> 26405792

Establishment of tandem mass spectrometric fingerprint of novel antineoplastic curcumin analogues using electrospray ionization.

H Awad1, U Das1, J Dimmock1, A El-Aneed1.   

Abstract

RATIONALE: Curcumin analogues are antineoplastic agents, designed based on the structure of the spice turmeric with structural modifications aiming at enhancing potency. The goal is to identify the common tandem mass spectrometric (MS/MS) behavior of 13 novel curcumin analogues. Such knowledge is critical for their biological assessment, including metabolite identification and pharmacokinetic evaluation.
METHODS: Both detection of the protonated molecules [M + H](+) of the synthesized compounds and determination of their exact molecular masses were achieved with hybrid quadrupole orthogonal time-of-flight mass spectrometry (QqTOF-MS). Low-energy collision-induced dissociation (CID)-MS/MS analysis was performed using triple quadrupole linear ion trap mass spectrometry (QqLIT-MS). Both instruments were equipped with an electrospray ionization (ESI) source. MS(3) and neutral loss experiments were performed using QqLIT-MS to confirm the genesis of the observed product ions.
RESULTS: Abundant [M + H](+) molecules were formed using the QqTOF-MS hybrid instrument with mass accuracies below 6 ppm. CID-MS/MS dissociation studies were centered on the piperidone ring of curcumin analogues; twelve common product ions have been identified from the fission of the various bonds within the piperidone moiety. There was a tendency for the formation of highly conjugated product ions, stabilized via resonance. The variety of the side-chain substituents at the nitrogen atom resulted in side-chain-specific product ions.
CONCLUSIONS: The ESI-CID-MS/MS analysis of curcumin analogues revealed a common fragmentation behavior of all tested compounds, which gave diagnostic product ions identified for each molecule. The established MS/MS behavior will be applied to determine metabolic by-products of curcumin analogues as well as to develop targeted identification/quantification methods within biological extracts.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26405792     DOI: 10.1002/rcm.7222

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  1 in total

1.  A Novel Triple Stage Ion Trap MS method validated for curcumin pharmacokinetics application: A comparison summary of the latest validated curcumin LC/MS methods.

Authors:  Wenji Li; Hilly Yang; Brian Buckley; Lujing Wang; Ah-Ng Kong
Journal:  J Pharm Biomed Anal       Date:  2018-04-17       Impact factor: 3.935

  1 in total