Literature DB >> 26403175

Accuracy of EuroSCORE II in patients undergoing minimally invasive mitral valve surgery.

Marco Moscarelli1, Giacomo Bianchi2, Rafik Margaryan2, Alfredo Cerillo2, Pierandrea Farneti2, Michele Murzi2, Marco Solinas2.   

Abstract

OBJECTIVES: EuroSCORE II has been implemented with the view to providing better performance than the previous logistic EuroSCORE. However, until now, no external validations have been carried out in the minimally invasive context. Therefore, we sought to validate the accuracy of EuroSCORE II in a retrospective series of consecutive patients undergoing minimally invasive mitral valve surgery.
METHODS: Data of 1609 consecutive patients who underwent minimally invasive mitral valve surgery in our institution were retrospectively reviewed. The accuracy of EuroSCORE II was assessed in terms of discrimination and calibration. Discrimination was tested via analysis of the area under the curve of receiver operator characteristic; calibration was achieved by calculating the observed versus expected mortality ratio and the Hosmer-Lemeshow test for test probability; global accuracy was assessed by using Brier's score; results were compared with the previous logistic EuroSCORE version. EuroSCORE II performance was also tested for discrimination of postoperative complications. Discrimination subgroup analysis was carried out for single surgeon results, and for high-risk patients those outliers were defined after boxplot analysis (EuroSCORE II ≥6%).
RESULTS: EuroSCORE II showed good discrimination power (area under the curve 0.846), and was statistically superior to logistic EuroSCORE (P = 0.01). In terms of calibration, both EuroSCORE II and logistic over-predicted mortality; with regard to adverse events, the discrimination of EuroSCORE II was adequate for acute renal failure, low-output syndrome and increased intensive care unit stay; area under the curve of receiver operating characteristic for high-risk patients with EuroSCORE ≥6% was suboptimal (0.654); single surgeon results did not influence the discrimination of EuroSCORE II.
CONCLUSIONS: EuroSCORE II showed good discrimination power in our series of minimally invasive mitral valve patients; however, it over-predicted mortality. Individual performance did not influence discrimination. Performance was suboptimal for prediction of complications and for high-risk subgroup in-hospital mortality.
© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Minimally invasive surgery; Mitral valve; Risk analysis/modelling; Statistics

Mesh:

Year:  2015        PMID: 26403175     DOI: 10.1093/icvts/ivv265

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  3 in total

1.  Cardioband for the treatment of secondary mitral regurgitation: a viable percutaneous option?

Authors:  Evin Yucel; Orlando Santana; Esteban Escolar; Christos G Mihos
Journal:  J Thorac Dis       Date:  2017-06       Impact factor: 2.895

2.  Minimally invasive mitral valve surgery in high-risk patients: operating outside the boxplot.

Authors:  Marco Moscarelli; Alfredo Cerillo; Thanos Athanasiou; Pierandrea Farneti; Giacomo Bianchi; Rafik Margaryan; Marco Solinas
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-03-06

3.  Minimally invasive approach compared to resternotomy for mitral valve surgery in patients with prior cardiac surgery: retrospective multicentre study based on the Netherlands Heart Registration.

Authors:  Jules R Olsthoorn; Samuel Heuts; Saskia Houterman; Jos G Maessen; Peyman Sardari Nia
Journal:  Eur J Cardiothorac Surg       Date:  2022-10-04       Impact factor: 4.534

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.