Literature DB >> 26398427

A ratiometric chemodosimeter for highly selective naked-eye and fluorogenic detection of cyanide.

Wei-Chi Lin1, Jiun-Wei Hu1, Kew-Yu Chen2.   

Abstract

A simple indole-based chemosensor (1) with a very low molecular weight of 207 g mol(-1) has been synthesized for the highly reactive and selective detection of CN(-) in aqueous media, even in the presence of other anions, such as F(-), Cl(-), Br(-), AcO(-), [Formula: see text] , SCN(-), [Formula: see text] , [Formula: see text] , [Formula: see text] , BzO(-), [Formula: see text] , and [Formula: see text] . The sensor achieves rapid detection of cyanide anion in 2 min, and the pseudo-first-order rate constant is estimated as 1.576 min(-1). The colorimetric and ratiometric fluorescent response of the sensor to CN(-) is attributable to the addition of CN(-) to the electron-deficient dicyanovinyl group of 1, which prevents intramolecular charge transfer. The sensing mechanism is supported by density functional theory and time-dependent density functional theory calculations. Moreover, sensor 1 exhibits both high accuracy in determining the concentration of CN(-) in real samples and 1-based test strips can conveniently detect CN(-) without any additional equipment. The detection limit of the sensor 1 (1.1 μM) for cyanide is lower than the maximum permissible level of CN(-) (1.9 μM) in drinking water.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemodosimeter; Colorimetric; Cyanide detection; Indole; Ratiometric fluorescence

Mesh:

Substances:

Year:  2015        PMID: 26398427     DOI: 10.1016/j.aca.2015.08.044

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  A sensitive and selective BINOL based ratiometric fluorescence sensor for the detection of cyanide ions.

Authors:  Sathishkumar Munusamy; Sathish Swaminathan; Dhanapal Jothi; Vivek Panyam Muralidharan; Sathiyanarayanan Kulathu Iyer
Journal:  RSC Adv       Date:  2021-04-27       Impact factor: 3.361

2.  Highly Sensitive Ratiometric Chemosensor and Biomarker for Cyanide Ions in the Aqueous Medium.

Authors:  Somenath Lohar; Koushik Dhara; Priya Roy; Santi P Sinha Babu; Pabitra Chattopadhyay
Journal:  ACS Omega       Date:  2018-08-30

3.  Substituted 2-Aminobenzothiazoles Salicylidenes Synthesis and Characterization as Cyanide Sensors in Aqueous Medium.

Authors:  Anas G Elsafy; Hala Sultan Al-Easa; Yousef M Hijji
Journal:  Sensors (Basel)       Date:  2018-07-10       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.