Literature DB >> 26398414

Transcatheter aortic valve replacement in bicuspid aortic valve disease.

Janusz Kochman1, Bartosz Rymuza, Zenon Huczek.   

Abstract

PURPOSE OF REVIEW: Bicuspid aortic valve stenosis is regarded as a relative contraindication for transcatheter aortic valve replacement (TAVR) according to current guidelines, as patients with bicuspid anatomy (BiAV) were excluded from landmark clinical trials.In this review, we will discuss the feasibilty, safety and outcomes of TAVR in BiAV, based upon the current literature and our own experience. RECENT
FINDINGS: The currently available data come from observational registries with low sample size, and only in a few were the results of TAVR in BiAV compared with those achieved in the cohort with tricuspid anatomy. TAVR proved to be technically feasible in selected BiAV patients, and the mid-term clinical outcomes are acceptable. Nevertheless, there are still some unresolved issues, such as long-term valve durability and the relatively high rate of paravalvular leakage.
SUMMARY: The existing literature supports the use of TAVR in selected high-risk BiAV patients, although the final role of this technique in this cohort of patients can only be established once a larger, preferably randomized, study comparing TAVR with surgery is performed.

Entities:  

Mesh:

Year:  2015        PMID: 26398414     DOI: 10.1097/HCO.0000000000000219

Source DB:  PubMed          Journal:  Curr Opin Cardiol        ISSN: 0268-4705            Impact factor:   2.161


  8 in total

1.  Treating patients with excessively large annuli with self-expanding transcatheter aortic valves: insights into supra-annular structures that anchor the prosthesis.

Authors:  Tian-Yuan Xiong; Yan-Biao Liao; Yi-Jian Li; Fei Chen; Yuanweixiang Ou; Xi Wang; Zi-Jie Wang; Xi Li; Zhen-Gang Zhao; Wei Meng; Yuan Feng; Mao Chen
Journal:  Herz       Date:  2020-09-03       Impact factor: 1.443

Review 2.  Transcatheter aortic valve implantation in patients with bicuspid valve morphology: a roadmap towards standardization.

Authors:  Tian-Yuan Xiong; Walid Ben Ali; Yuan Feng; Kentaro Hayashida; Hasan Jilaihawi; Azeem Latib; Michael Kang-Yin Lee; Martin B Leon; Raj R Makkar; Thomas Modine; Christoph Naber; Yong Peng; Nicolo Piazza; Michael J Reardon; Simon Redwood; Ashok Seth; Lars Sondergaard; Edgar Tay; Didier Tchetche; Wei-Hsian Yin; Mao Chen; Bernard Prendergast; Darren Mylotte
Journal:  Nat Rev Cardiol       Date:  2022-06-20       Impact factor: 32.419

3.  Long-Term Mortality After TAVI for Bicuspid vs. Tricuspid Aortic Stenosis: A Propensity-Matched Multicentre Cohort Study.

Authors:  Aleksandra Gasecka; Michał Walczewski; Adam Witkowski; Maciej Dabrowski; Zenon Huczek; Radosław Wilimski; Andrzej Ochała; Radosław Parma; Piotr Scisło; Bartosz Rymuza; Karol Zbroński; Piotr Szwed; Marek Grygier; Anna Olasińska-Wiśniewska; Dariusz Jagielak; Radosław Targoński; Grzegorz Opolski; Janusz Kochman
Journal:  Front Cardiovasc Med       Date:  2022-06-21

4.  Balloon sizing during transcatheter aortic valve implantation : Comparison of different valve morphologies.

Authors:  Y-N Xu; T-Y Xiong; Y-J Li; Y-B Liao; Z-G Zhao; X Wei; Y Feng; M Chen
Journal:  Herz       Date:  2018-06-05       Impact factor: 1.443

5.  Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis utilizing the next-generation fully retrievable and repositionable valve system: mid-term results from a prospective multicentre registry.

Authors:  Janusz Kochman; Karol Zbroński; Łukasz Kołtowski; Radosław Parma; Andrzej Ochała; Zenon Huczek; Bartosz Rymuza; Radosław Wilimski; Maciej Dąbrowski; Adam Witkowski; Piotr Scisło; Marek Grygier; Maciej Lesiak; Grzegorz Opolski
Journal:  Clin Res Cardiol       Date:  2019-09-02       Impact factor: 5.460

6.  Comparison of the results of transcatheter aortic valve implantation in patients with bicuspid and tricuspid aortic valve.

Authors:  Piotr A Chodór; Krzysztof Wilczek; Karolina Chodór-Rozwadowska; Roman Przybylski; Jan Głowacki; Tomasz Niklewski; Łukasz Włoch; Mariusz Gąsior; Marian Zembala; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2021-03-27       Impact factor: 1.426

7.  Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation.

Authors:  Xin Meng; Yandan Sun; Wei Bai; Yuxi Li; Shengjun Tuo; Liang Cao; Mengmeng Du; Yang Liu; Ping Jin; Jian Yang; Liwen Liu
Journal:  Ann Transl Med       Date:  2022-01

8.  Procedural and clinical outcomes of transcatheter aortic valve replacement in bicuspid aortic valve patients: a systematic review and meta-analysis.

Authors:  Cheng-Hao Jacky Chen; Henry Jiang; Owen Martin; Ashley R Wilson-Smith
Journal:  Ann Cardiothorac Surg       Date:  2022-07
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.