Literature DB >> 26395983

Erratum to: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

Shih-Jie Lin1, Chien-Ying Lee1, Kuo-Chin Huang1,2, Kuo-Ti Peng1,2, Tsan-Wen Huang3,4, Mel S Lee5,2, Robert Wen-Wei Hsu6,7, Wun-Jer Shen8.   

Abstract

Entities:  

Year:  2015        PMID: 26395983      PMCID: PMC4580295          DOI: 10.1186/s13018-015-0293-6

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


× No keyword cloud information.

Erratum

After publication of the original article [1] it came to our attention that there were errors in Table 3. The data in the first parameter [preoperative coronal MA(°)] was incorrect and has been corrected in Table 3 below.
Table 3

Radiographic data of patients with genu varum

Group AGroup B
n = 39 n = 51
ParametersMean ± SD (min-max)Mean ± SD (min-max) p-value
Preoperative coronal MA (°)159.7 ± 3.9 (150–165)158.3 ± 4.2 (143–165)0.443
Postoperative coronal MA (°)179.5 ± 1.7 (178–184)177.9 ± 2.4 (176–181)0.572
Frontal femoral angle (°)90.6 ± 1.7 (86–91)89.7 ± 1.5 (84–91)0.414
Sagittal femoral angle (°)1.6 ± 1.2 (0–6)3.5 ± 2.8 (1–7)<0.001*
Femoral rotation angle (°)1.0 ± 0.7 (0–3)1.7 ± 1.1 (0–6)0.127
Frontal tibial angle (°)90.0 ± 0.5 (89–91)89.9 ± 1.4 (88–91)0.714
Sagittal tibial angle (°)87.9 ± 1.8 (84–90)87.7 ± 2.2 (80–91)0.518

Group A: osteoarthritis with genu varum and underwent computer-assisted surgery total knee arthroplasty (CAS-TKA)

Group B: osteoarthritis with genu varum and underwent conventional TKA

p values for between-group comparison were determined by Mann–Whitney U test

*Statistically significant (p < 0.05)

Radiographic data of patients with genu varum Group A: osteoarthritis with genu varum and underwent computer-assisted surgery total knee arthroplasty (CAS-TKA) Group B: osteoarthritis with genu varum and underwent conventional TKA p values for between-group comparison were determined by Mann–Whitney U test *Statistically significant (p < 0.05)
  1 in total

1.  Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

Authors:  Shih-Jie Lin; Chien-Ying Lee; Kuo-Chin Huang; Kuo-Ti Peng; Tsan-Wen Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  J Orthop Surg Res       Date:  2015-09-02       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.