Literature DB >> 26394344

Indications and Frequency for the Use of Cone Beam Computed Tomography for Implant Treatment Planning in a Specialty Clinic.

Michael M Bornstein, Odette Engel Brügger, Simone F M Janner, Ulrike Kuchler, Vivianne Chappuis, Reinhilde Jacobs, Daniel Buser.   

Abstract

PURPOSE: To analyze the indications and frequency for three-dimensional (3D) imaging for implant treatment planning in a pool of patients referred to a specialty clinic over a 3-year period.
MATERIALS AND METHODS: All patients who received dental implants between 2008 and 2010 at the Department of Oral Surgery and Stomatology at the University of Bern were included in the study. The influence of age, gender, and time of treatment (2008 to 2010) on the frequency of use of two-dimensional (2D) radiographic imaging modalities alone or in combination with 3D cone beam computed tomography (CBCT) scans was analyzed. Furthermore, the influence of the indication, location, and need for bone augmentation on the frequency of use of 2D imaging modalities alone or in combination with CBCT was evaluated.
RESULTS: In all, 1,568 patients (792 women and 776 men) received 2,279 implants. Overall, 633 patients (40.4%) were analyzed with 2D imaging procedures alone. CBCT was performed in 935 patients (59.6%). There was a statistically significant increase in CBCT between 2008 and 2010. Patients older than 55 years received a CBCT scan in addition to 2D radiographic imaging statistically significantly more often. Additional 3D imaging was most frequently performed in the posterior maxilla, whereas 2D radiographs alone exhibited the highest frequency in the anterior mandible. The combination of 2D with CBCT was used predominantly for implant placement with simultaneous or staged guided bone regeneration or sinus elevation.
CONCLUSION: Based on these findings from a specialty clinic, the use of additional CBCT imaging for implant treatment planning is influenced by the indication, location, local anatomy (including the need for bone augmentation), and the age of the patient.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26394344     DOI: 10.11607/jomi.4081

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Metallic materials in the exomass impair cone beam CT voxel values.

Authors:  Amanda P Candemil; Benjamin Salmon; Deborah Q Freitas; Glaucia Mb Ambrosano; Francisco Haiter-Neto; Matheus L Oliveira
Journal:  Dentomaxillofac Radiol       Date:  2018-03-27       Impact factor: 2.419

2.  Is MRI a viable alternative to CT/CBCT to identify the course of the inferior alveolar nerve in relation to the roots of the third molars?

Authors:  Florian Beck; Stephanie Austermann; Kristina Bertl; Christian Ulm; Stefan Lettner; Andrea Toelly; André Gahleitner
Journal:  Clin Oral Investig       Date:  2020-12-07       Impact factor: 3.573

3.  Accuracy of Software-Based Three-Dimensional Root Canal Length Measurements Using Cone-Beam Computed Tomography.

Authors:  J P Tchorz; K T Wrbas; C Von See; K Vach; Sbm Patzelt
Journal:  Eur Endod J       Date:  2018-11-13

4.  Condylar jugular diverticulum: A report of 3 cases.

Authors:  Rohan Jagtap; Taggreed Wazzan; Matthew Hansen; Deeba Kashtwari
Journal:  Imaging Sci Dent       Date:  2019-09-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.