Literature DB >> 26394338

Comparison of the Primary Stability of Two Implant Designs in Two Different Bone Types: An In Vitro Study.

Hakan Bilhan, Caglar Bilmenoglu, Aliye Ceren Urgun, Gokcen Ates, Canan Bural, Altug Cilingir, Onur Geckili.   

Abstract

PURPOSE: Achievement of primary stability upon surgical placement of dental implants is a key factor for successful osseointegration and depends mainly on implant-related factors. The aim of this study was to compare and assess the primary stability of implants with active and regular threads in type 2 as well as type 4 bone.
MATERIALS AND METHODS: Fresh cow vertebrae and a pelvis were used as models of type 4 bone and type 2 bone, respectively. Implants with two different designs-regular-threaded and active-threaded-both 4.3 mm wide and 13 mm long, were placed in both types of bone (n = 80). Stability measurements were completed by four prosthodontists using two different Periotest devices and resonance frequency analysis. Statistical analyses were performed with the Mann-Whitney U test.
RESULTS: No statistically significant differences were found between the implant types in either type of bone in the stability measured with different methods. For both implant types, the mean resonance frequency values in type 2 bone were statistically significantly higher than in type 4 bone, whereas the mean Periotest values in type 2 bone were statistically significantly lower than in type 4 bone.
CONCLUSION: Within the limitations of this in vitro study in bone types 2 and 4, the active-threaded implant, which was invented to increase primary stability, did not show higher primary stability compared to a regular-threaded implant.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26394338     DOI: 10.11607/jomi.3939

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

Authors:  Mirko Mikic; Zoran Vlahovic; Momir Stevanović; Zoran Arsic; Rasa Mladenovic
Journal:  Tomography       Date:  2022-05-11

2.  In vitro comparison of primary stability of two implant designs in D3 bone.

Authors:  J González-Serrano; R Ortega-Aranegui; J López-Quiles
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2017-07-01

3.  An In Vitro Evaluation of Primary Stability Values for Two Differently Designed Implants to Suit Immediate Loading in Very Soft Bone.

Authors:  Dirk Krischik; Selen Ergin Tokgöz; Andreas van Orten; Anton Friedmann; Hakan Bilhan
Journal:  Dent J (Basel)       Date:  2021-01-08

Review 4.  Accuracy of additive manufacturing in stomatology.

Authors:  Yao Tang; Yunfan Zhang; Zhaoqiang Meng; Qiannan Sun; Liying Peng; Lingyun Zhang; Wenhsuan Lu; Wei Liang; Gui Chen; Yan Wei
Journal:  Front Bioeng Biotechnol       Date:  2022-08-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.