Literature DB >> 26392835

A pump-free membrane-controlled perfusion microfluidic platform.

Vasiliy N Goral1, Elizabeth Tran1, Po Ki Yuen1.   

Abstract

In this article, we present a microfluidic platform for passive fluid pumping for pump-free perfusion cell culture, cell-based assay, and chemical applications. By adapting the passive membrane-controlled pumping principle from the previously developed perfusion microplate, which utilizes a combination of hydrostatic pressure generated by different liquid levels in the wells and fluid wicking through narrow strips of a porous membrane connecting the wells to generate fluid flow, a series of pump-free membrane-controlled perfusion microfluidic devices was developed and their use for pump-free perfusion cell culture and cell-based assays was demonstrated. Each pump-free membrane-controlled perfusion microfluidic device comprises at least three basic components: an open well for generating fluid flow, a micron-sized deep chamber/channel for cell culture or for fluid connection, and a wettable porous membrane for controlling the fluid flow. Each component is fluidically connected either by the porous membrane or by the micron-sized deep chamber/channel. By adapting and incorporating the passive membrane-controlled pumping principle into microfluidic devices, all the benefits of microfluidic technologies, such as small sample volumes, fast and efficient fluid exchanges, and fluid properties at the micro-scale, can be fully taken advantage of with this pump-free membrane-controlled perfusion microfluidic platform.

Year:  2015        PMID: 26392835      PMCID: PMC4560713          DOI: 10.1063/1.4930120

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  17 in total

1.  Theoretical analysis of molecular diffusion in pressure-driven laminar flow in microfluidic channels.

Authors:  A E Kamholz; P Yager
Journal:  Biophys J       Date:  2001-01       Impact factor: 4.033

2.  Perfusion-based microfluidic device for three-dimensional dynamic primary human hepatocyte cell culture in the absence of biological or synthetic matrices or coagulants.

Authors:  Vasiliy N Goral; Yi-Cheng Hsieh; Odessa N Petzold; Jeffery S Clark; Po Ki Yuen; Ronald A Faris
Journal:  Lab Chip       Date:  2010-11-08       Impact factor: 6.799

3.  An artificial liver sinusoid with a microfluidic endothelial-like barrier for primary hepatocyte culture.

Authors:  Philip J Lee; Paul J Hung; Luke P Lee
Journal:  Biotechnol Bioeng       Date:  2007-08-01       Impact factor: 4.530

4.  Cell-free protein expression in a microchannel array with passive pumping.

Authors:  Ruba Khnouf; David J Beebe; Z Hugh Fan
Journal:  Lab Chip       Date:  2008-10-22       Impact factor: 6.799

5.  A microfluidic 3D hepatocyte chip for drug toxicity testing.

Authors:  Yi-Chin Toh; Teck Chuan Lim; Dean Tai; Guangfa Xiao; Danny van Noort; Hanry Yu
Journal:  Lab Chip       Date:  2009-04-20       Impact factor: 6.799

6.  Bile canaliculi formation by aligning rat primary hepatocytes in a microfluidic device.

Authors:  Yosuke Nakao; Hiroshi Kimura; Yasuyuki Sakai; Teruo Fujii
Journal:  Biomicrofluidics       Date:  2011-06-29       Impact factor: 2.800

7.  Multi-cellular 3D human primary liver cell culture elevates metabolic activity under fluidic flow.

Authors:  Mandy B Esch; Jean-Matthieu Prot; Ying I Wang; Paula Miller; Jose Ricardo Llamas-Vidales; Brian A Naughton; Dawn R Applegate; Michael L Shuler
Journal:  Lab Chip       Date:  2015-05-21       Impact factor: 6.799

8.  A Cell Programmable Assay (CPA) chip.

Authors:  Jongil Ju; Jay Warrick; David J Beebe
Journal:  Lab Chip       Date:  2010-07-08       Impact factor: 6.799

9.  A microfluidic platform for 3-dimensional cell culture and cell-based assays.

Authors:  Minseok S Kim; Ju Hun Yeon; Je-Kyun Park
Journal:  Biomed Microdevices       Date:  2007-02       Impact factor: 2.838

10.  A novel 3D mammalian cell perfusion-culture system in microfluidic channels.

Authors:  Yi-Chin Toh; Chi Zhang; Jing Zhang; Yuet Mei Khong; Shi Chang; Victor D Samper; Danny van Noort; Dietmar W Hutmacher; Hanry Yu
Journal:  Lab Chip       Date:  2007-01-23       Impact factor: 6.799

View more
  4 in total

1.  Razor-printed sticker microdevices for cell-based applications.

Authors:  Loren E Stallcop; Yasmín R Álvarez-García; Ana M Reyes-Ramos; Karla P Ramos-Cruz; Molly M Morgan; Yatao Shi; Lingjun Li; David J Beebe; Maribella Domenech; Jay W Warrick
Journal:  Lab Chip       Date:  2018-01-30       Impact factor: 6.799

2.  Pumpless platform for high-throughput dynamic multicellular culture and chemosensitivity evaluation.

Authors:  Zhehuan Chen; Songmin He; Jenny Zilberberg; Woo Lee
Journal:  Lab Chip       Date:  2019-01-15       Impact factor: 6.799

3.  Hand-Powered Elastomeric Pump for Microfluidic Point-of-Care Diagnostics.

Authors:  Gangadhar Eluru; Jayesh Vasudeva Adhikari; Priyalaxita Chanda; Sai Siva Gorthi
Journal:  Micromachines (Basel)       Date:  2020-01-07       Impact factor: 2.891

4.  Design and Fabrication of the Vertical-Flow Bioreactor for Compaction Hepatocyte Culture in Drug Testing Application.

Authors:  Liang Zhu; Zhenfeng Wang; Huanming Xia; Hanry Yu
Journal:  Biosensors (Basel)       Date:  2021-05-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.