Literature DB >> 26392154

CORRELATIONS AMONG ULTRASONOGRAPHIC MEASUREMENTS OF OPTIC NERVE SHEATH DIAMETER, AGE, AND BODY WEIGHT IN CLINICALLY NORMAL HORSES.

Stacy D Cooley1, Peter V Scrivani1, Margret S Thompson1, Nita L Irby1, Thomas J Divers1, Hollis N Erb2.   

Abstract

Early diagnosis of high intracranial pressure (ICP) is critical for minimizing progressive brain injury due to reduced cerebral perfusion. In people, detecting enlargement of the optic nerve sheath diameter (ONSD) by transpalpebral ultrasonography has been found to be an accurate test for high ICP. Aims of this prospective, observational, cross-sectional study were to test hypotheses that (1) ultrasonographic measurement of ONSD would be repeatable in horses, (2) have acceptable interobserver agreement, and (3) would be correlated with age and body weight. The sample population included 48 horses without clinical signs of high ICP and with varying ages and body weights. Two observers independently performed ONSD measurements in both eyes. All measurements ranged from 2.6 to 6.5 mm. The mean difference of repeated measures within observers was ≤0.1 mm and the coefficients of variation ranged from 5.0% to 8.8%. The mean difference of measures between observers was ≤0.2 mm. After correcting for performing multiple tests, no significant rank correlation (all r < 0.4 [absolute value]) was detected between ONSD and age or body weight. However, we observed smaller ONSD in foals versus adults (all P ≤ 0.002). In the foals, all observed measures of rostrocaudal and dorsoventral ONSD were <5 mm. In the adults, all observed measures of rostrocaudal and dorsoventral ONSD were ≤6.5 mm. Findings indicated that ultrasonographic ONSD measurement is a feasible test for use in horses of varying ages and sizes. Further investigation of this ultrasonographic measure as a clinical test for horse with suspected high ICP is warranted.
© 2015 American College of Veterinary Radiology.

Entities:  

Keywords:  horse; intracranial pressure; optic nerve sheath diameter; ultrasonography

Mesh:

Year:  2015        PMID: 26392154     DOI: 10.1111/vru.12300

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  3 in total

1.  Intracranial pressure in the American Alligator (Alligator mississippiensis): reptilian meninges and orthostatic gradients.

Authors:  Tatyana Kondrashova; Joshua Blanchard; Lucas Knoche; James Potter; Bruce A Young
Journal:  J Comp Physiol A Neuroethol Sens Neural Behav Physiol       Date:  2019-12-06       Impact factor: 1.836

Review 2.  The effect of laparoscopy on intracranial pressure as measured by optic nerve sheath diameter: A review.

Authors:  Kevin G Mitchell; Ryan B Appleby; Melissa D Sinclair; Ameet Singh
Journal:  Can Vet J       Date:  2022-04       Impact factor: 1.075

Review 3.  Optic Nerve Ultrasound Evaluation in Animals and Normal Subjects.

Authors:  Livio Vitiello; Maddalena De Bernardo; Luigi Capasso; Palmiro Cornetta; Nicola Rosa