Literature DB >> 26391454

Absolute and relative intrasession reliability of surface EMG variables for voluntary precise forearm movements.

Daniel Carius1, Patrick Kugler2, Hans-Marten Kuhwald3, Rainer Wollny3.   

Abstract

The reliability of surface electromyography (EMG) derived parameters is of high importance, but there is distinct lack of studies concerning the reliability during dynamic contractions. Especially Amplitude, Fourier and Wavelet parameter in conjunction have not been tested so far. The interpretation of the EMG variables might be difficult because the movement itself introduces additional factors that affect its characteristics. The aim of this study was to determine the relative and absolute intrasession reliability of electromyographic (EMG) variables of selected arm muscles during concurrent precise elbow extension/flexion movements at different force levels and movement speed. Participants (all-male: n = 17, range 20-32 years) were asked to adapt to a gross-motor visuomotor tracking task (elbow extension/flexion movement) using a custom-built lever arm apparatus. After sufficient adaptation surface electromyography was used to record the electrical activity of mm. biceps brachii, brachioradialis and triceps brachii, and the signal amplitude (RMS [μV]) and the mean frequency of the power spectrum (MNF [Hz]) were computed. Additionally Wavelet analysis was used. Relative reproducibility (intraclass correlation) for signal amplitude, mean frequency of the power spectrum and Wavelet intensity during dynamic contractions was fair to good, independent of force level and movement speed (ICC = 0.71-0.98). The amount of absolute intrasession reliability (coefficient of variation) of EMG variables depends on muscle and force level.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Concurrent movements; Controlled movements; Electromyography; Intensity patterns; Reliability; Reproducibility; Sources of variation; Variability; Wavelets

Mesh:

Year:  2015        PMID: 26391454     DOI: 10.1016/j.jelekin.2015.09.001

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  5 in total

1.  Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions.

Authors:  Graeme G Sorbie; Michael J Williams; David W Boyle; Alexander Gray; James Brouner; Neil Gibson; Julien S Baker; Chris Easton; Ukadike C Ugbolue
Journal:  Front Physiol       Date:  2018-03-29       Impact factor: 4.566

2.  The different role of each head of the triceps brachii muscle in elbow extension.

Authors:  Erica Kholinne; Rizki Fajar Zulkarnain; Yu Cheng Sun; SungJoon Lim; Jae-Myeung Chun; In-Ho Jeon
Journal:  Acta Orthop Traumatol Turc       Date:  2018-03-02       Impact factor: 1.511

3.  Reliability of Vibroarthrography to Assess Knee Joint Sounds in Motion.

Authors:  Kristin Kalo; Daniel Niederer; Rainer Sus; Keywan Sohrabi; Volker Groß; Lutz Vogt
Journal:  Sensors (Basel)       Date:  2020-04-02       Impact factor: 3.576

4.  Exhausting repetitive piano tasks lead to local forearm manifestation of muscle fatigue and negatively affect musical parameters.

Authors:  Etienne Goubault; Felipe Verdugo; Justine Pelletier; Caroline Traube; Mickaël Begon; Fabien Dal Maso
Journal:  Sci Rep       Date:  2021-04-14       Impact factor: 4.379

Review 5.  Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review.

Authors:  Andrea Merlo; Maria Chiara Bò; Isabella Campanini
Journal:  Sensors (Basel)       Date:  2021-11-03       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.