Literature DB >> 26388656

A Modified Error in Constitutive Equation Approach for Frequency-Domain Viscoelasticity Imaging Using Interior Data.

Manuel I Diaz1, Wilkins Aquino1, Marc Bonnet2.   

Abstract

This paper presents a methodology for the inverse identification of linearly viscoelastic material parameters in the context of steady-state dynamics using interior data. The inverse problem of viscoelasticity imaging is solved by minimizing a modified error in constitutive equation (MECE) functional, subject to the conservation of linear momentum. The treatment is applicable to configurations where boundary conditions may be partially or completely underspecified. The MECE functional measures the discrepancy in the constitutive equations that connect kinematically admissible strains and dynamically admissible stresses, and also incorporates the measurement data in a quadratic penalty term. Regularization of the problem is achieved through a penalty parameter in combination with the discrepancy principle due to Morozov. Numerical results demonstrate the robust performance of the method in situations where the available measurement data is incomplete and corrupted by noise of varying levels.

Entities:  

Year:  2015        PMID: 26388656      PMCID: PMC4570248          DOI: 10.1016/j.cma.2015.07.025

Source DB:  PubMed          Journal:  Comput Methods Appl Mech Eng        ISSN: 0045-7825            Impact factor:   6.756


  11 in total

Review 1.  Elastography: ultrasonic estimation and imaging of the elastic properties of tissues.

Authors:  J Ophir; S K Alam; B Garra; F Kallel; E Konofagou; T Krouskop; T Varghese
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

2.  Evaluation of an iterative reconstruction method for quantitative elastography.

Authors:  M M Doyley; P M Meaney; J C Bamber
Journal:  Phys Med Biol       Date:  2000-06       Impact factor: 3.609

Review 3.  Selected methods for imaging elastic properties of biological tissues.

Authors:  James F Greenleaf; Mostafa Fatemi; Michael Insana
Journal:  Annu Rev Biomed Eng       Date:  2003-04-10       Impact factor: 9.590

4.  An inverse problem approach for elasticity imaging through vibroacoustics.

Authors:  Miguel A Aguiló; Wilkins Aquino; John C Brigham; Mostafa Fatemi
Journal:  IEEE Trans Med Imaging       Date:  2010-03-22       Impact factor: 10.048

5.  Imaging anisotropic and viscous properties of breast tissue by magnetic resonance-elastography.

Authors:  R Sinkus; M Tanter; S Catheline; J Lorenzen; C Kuhl; E Sondermann; M Fink
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

6.  A unified view of imaging the elastic properties of tissue.

Authors:  Kevin J Parker; Lawrence S Taylor; Sheryl Gracewski; Deborah J Rubens
Journal:  J Acoust Soc Am       Date:  2005-05       Impact factor: 1.840

7.  Shear modulus reconstruction in dynamic elastography: time harmonic case.

Authors:  Eunyoung Park; Antoinette M Maniatty
Journal:  Phys Med Biol       Date:  2006-07-12       Impact factor: 3.609

Review 8.  Imaging of the elastic properties of tissue--a review.

Authors:  L Gao; K J Parker; R M Lerner; S F Levinson
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

9.  Inverse Material Identification in Coupled Acoustic-Structure Interaction using a Modified Error in Constitutive Equation Functional.

Authors:  James E Warner; Manuel I Diaz; Wilkins Aquino; Marc Bonnet
Journal:  Comput Mech       Date:  2014-09       Impact factor: 4.014

10.  Large Scale Parameter Estimation Problems in Frequency-Domain Elastodynamics Using an Error in Constitutive Equation Functional.

Authors:  Biswanath Banerjee; Timothy F Walsh; Wilkins Aquino; Marc Bonnet
Journal:  Comput Methods Appl Mech Eng       Date:  2012-09-13       Impact factor: 6.756

View more
  2 in total

1.  Modified error in constitutive equations (MECE) approach for ultrasound elastography.

Authors:  Susanta Ghosh; Zilong Zou; Olalekan Babaniyi; Wilkins Aquino; Manuel I Diaz; Mahdi Bayat; Mostafa Fatemi
Journal:  J Acoust Soc Am       Date:  2017-10       Impact factor: 1.840

2.  Ultrasound elastography using a regularized modified error in constitutive equations (MECE) approach: a comprehensive phantom study.

Authors:  S Ghavami; O Babaniyi; S Adabi; D Rosen; A Alizad; W Aquino; M Fatemi
Journal:  Phys Med Biol       Date:  2020-11-24       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.