Determining the requirements, section quantity, and dimension of the virtual occlusal record.

Eneko Solaberrieta1, Agustin Arias2, Aritza Brizuela3, Xabier Garikano4, Guillermo Pradies5.   

Abstract

STATEMENT OF PROBLEM: Conventional methods associated with many processes in dentistry are being replaced by methods that use digital technology. One of these processes is the making of occlusal records for the positioning of casts in a virtual articulator. Conventional interocclusal records and the articulator are currently being replaced by the intraoral virtual occlusal record and the virtual articulator.
PURPOSE: The purpose of this study was to determine the requirements, quantity, and dimensions of the virtual occlusal record procedure in order to locate the mandibular cast's 3-dimensional (3D) spatial position in reference to its corresponding maxillary cast on a virtual articulator.
MATERIAL AND METHODS: For the conventional procedure, 6 sets of casts were located in maximal intercuspal position without any interocclusal record. Then, using articulating paper, the occlusal contacts were determined. Afterward, the occlusal relationships and stone cast were digitized with a 3D scanner. To locate the maxillary cast, the occlusal contacts were compared by taking different sections as the virtual occlusal record. Finally, the optimum dimension of the virtual occlusal record was determined.
RESULTS: This study determines the requirements, quantity, and dimensions of the virtual occlusal record using current reverse engineering tools. The combinations of the sections were first determined as follows: 3 sections (2 lateral and 1 frontal) and 2 lateral sections proved to be the most accurate. Then, the predictive values (PV) for dimension determination for the left-right lateral combination were calculated.
CONCLUSIONS: The main conclusion of this study was that the combination of left and right lateral occlusal records was the most convenient. Additionally, the minimum optimum dimension for a virtual occlusal record was 12×15 mm.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2015        PMID: 26386482     DOI: 10.1016/j.prosdent.2015.06.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  2 in total

1.  [Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method].

Authors:  L L Li; Y J Zhao; H Chen; Y Wang; Y C Sun
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-02-18

Review 2.  Intraoral Scanner Technologies: A Review to Make a Successful Impression.

Authors:  Raphaël Richert; Alexis Goujat; Laurent Venet; Gilbert Viguie; Stéphane Viennot; Philip Robinson; Jean-Christophe Farges; Michel Fages; Maxime Ducret
Journal:  J Healthc Eng       Date:  2017-09-05       Impact factor: 2.682

  2 in total