Literature DB >> 26385821

Tumour Response in Uveal Melanomas Treated with Proton Beam Therapy.

C Maschi1, J Thariat2, J Herault2, J-P Caujolle3.   

Abstract

AIMS: Post-proton therapy surveillance of uveal melanomas relies on decreased thickness on repeat ultrasound B every 6 months for 2 years and yearly thereafter. Earlier pseudoprogression, a phenomenon described in other tumour types within the first months of irradiation, can also be observed in uveal melanomas and may lead to inappropriate enucleation. The Collaborative Ocular Melanoma Study (COMS) has defined ultrasound criteria to identify tumour progression after brachytherapy. We aimed to determine the reliability of ultrasound as a means to measure tumour height after proton therapy and predict local relapse.
MATERIALS AND METHODS: All 1992-2012 consecutive patients with at least three ultrasound B measurements during follow-up were included.
RESULTS: There were 55 local relapses of 886 patients (6.2%). Ultrasound B reliability was highest at 24 months, with specificity higher than 95% starting at 18 months.
CONCLUSION: Before 18 months post-proton therapy, the risk of falsely concluding in favour of a relapse exceeds 5% and should prompt repeat measurements 3 and 6 months later but should not prompt enucleation without further clinical assessment.
Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Enucleation; proton therapy; regression; tumour response; ultrasound; uveal melanoma

Mesh:

Year:  2015        PMID: 26385821     DOI: 10.1016/j.clon.2015.08.007

Source DB:  PubMed          Journal:  Clin Oncol (R Coll Radiol)        ISSN: 0936-6555            Impact factor:   4.126


  6 in total

1.  Uveal melanoma: quantitative evaluation of diffusion-weighted MR imaging in the response assessment after proton-beam therapy, long-term follow-up.

Authors:  Pietro Valerio Foti; Antonio Longo; Michele Reibaldi; Andrea Russo; Giuseppe Privitera; Corrado Spatola; Luigi Raffaele; Vincenzo Salamone; Renato Farina; Stefano Palmucci; Andrea Musumeci; Rosario Caltabiano; Marco Ragusa; Cesare Mariotti; Teresio Avitabile; Pietro Milone; Giovanni Carlo Ettorre
Journal:  Radiol Med       Date:  2016-10-17       Impact factor: 3.469

2.  Response criteria for intraocular retinoblastoma: RB-RECIST.

Authors:  Jesse L Berry; Francis L Munier; Brenda L Gallie; Ashley Polski; Sona Shah; Carol L Shields; Dan S Gombos; Kathleen Ruchalski; Christina Stathopoulos; Rachana Shah; Rima Jubran; Jonathan W Kim; Prithvi Mruthyunjaya; Brian P Marr; Matthew W Wilson; Rachel C Brennan; Guillermo L Chantada; Murali M Chintagumpala; A Linn Murphree
Journal:  Pediatr Blood Cancer       Date:  2021-02-23       Impact factor: 3.167

3.  Clinical Outcomes of Proton Beam Therapy for Choroidal Melanoma at a Single Institute in Korea.

Authors:  Tae Wan Kim; Euncheol Choi; Jeonghoon Park; Dong-Ho Shin; Su Kyung Jung; Susie Seok; Kwan Ho Cho; Joo-Young Kim; Dae Yong Kim; Tae Hyun Kim; Yang Kwon Suh; Yeon Joo Kim; Sung Ho Moon
Journal:  Cancer Res Treat       Date:  2017-04-19       Impact factor: 4.679

4.  Treatment of Uveal Melanoma With Radioactive Iodine 125 Implant Compared With Proton Beam Radiotherapy.

Authors:  James P Bolling; Roi Dagan; Michael Rutenberg; Maria Mamalui-Hunter; Steven J Buskirk; Michael G Heckman; Alexander P Hochwald; Roelf Slopsema
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2021-12-22

5.  Radiological and clinical findings in uveal melanoma treated by plaque interventional radiotherapy (brachytherapy): Visual atlas and literature review on response assessment.

Authors:  Bruno Fionda; Monica Maria Pagliara; Valentina Lancellotta; Carmela Grazia Caputo; Calogero Casà; Maria Grazia Sammarco; Elisa Placidi; Patrizia Cornacchione; Francesco Boselli; Roberto Iezzi; Cesare Colosimo; Luca Tagliaferri; Maria Antonietta Blasi
Journal:  J Contemp Brachytherapy       Date:  2022-02-04

6.  Convolutional Neural Networks Cascade for Automatic Pupil and Iris Detection in Ocular Proton Therapy.

Authors:  Luca Antonioli; Andrea Pella; Rosalinda Ricotti; Matteo Rossi; Maria Rosaria Fiore; Gabriele Belotti; Giuseppe Magro; Chiara Paganelli; Ester Orlandi; Mario Ciocca; Guido Baroni
Journal:  Sensors (Basel)       Date:  2021-06-27       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.