Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement.

Matthew J Hoyt1, Jessica Hathaway2, Roseanne Palmer2, Michael Beach2.   

Abstract

OBJECTIVE: Determine predictors of permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR).
DESIGN: A retrospective chart review of patients undergoing TAVR at the authors' institution. Extracted data included patient demographics, electrocardiogram, procedural, and echocardiographic data. Multivariate regression was performed to identify associations with PPM implantation.
SETTING: Single-center academic hospital. PARTICIPANTS: Patients undergoing TAVR.
INTERVENTIONS: This study was retrospective. No interventions were performed on patients.
MEASUREMENTS AND MAIN RESULTS: Baseline electrocardiogram, Society of Thoracic Surgeons score, age, and echocardiographic parameters were not predictors of PPM implantation. However, multiple deployments was a risk factor, and degree of paravalvular leak trended toward significance. Ten patients required placement of a 2nd valve, or valve-in-valve (VIV). Of the 10 patients with VIV, 5 (50%) required a PPM, compared with 8 (14%) of 56 patients with a single valve (OR 6.0, p = 0.02). PPM implantation occurred in 5 (42%) patients with no leak, 8 (19%) patients with trace leak, and no patients with mild or moderate leak (p = 0.085). In patients with no or trace leak, VIV increased the likelihood of PPM from 17.4% to 62.5% (OR 7.9, p = 0.006). For the 42 patients with trace leak, VIV increased the likelihood of PPM from 11.4% to 57.1% (OR 10.33, p = 0.005).
CONCLUSIONS: The authors found VIV placement, and likely degree of paravalvular leak, to be predictors of PPM placement. VIV and the degree of leak may be useful markers for postoperative prophylactic pacemaker placement.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ECG; ECHO; Transcatheter aortic valve replacement; pacemaker; paravalvular leak

Mesh:

Year:  2015        PMID: 26384625     DOI: 10.1053/j.jvca.2015.06.001

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  2 in total

1.  Permanent Pacing After Transcatheter Aortic Valve Implantation: Incidence, Predictors and Evolution of Left Ventricular Function.

Authors:  Cláudio Monteiro; Andres Di Leoni Ferrari; Paulo Ricardo Avancini Caramori; Luiz Antonio Ferreira Carvalho; Dimytri Alexandre de Alvim Siqueira; Luiz Eduardo Koenig São Thiago; Marco Perin; Valter C de Lima; Enio Guérios; Fabio Sandoli De Brito Junior
Journal:  Arq Bras Cardiol       Date:  2017-11-27       Impact factor: 2.000

2.  Clinical value of the 20% logistic EuroSCORE cut-off for selecting TAVI candidates: a single-centre cohort study analysis.

Authors:  Guram Imnadze; Steffen Hofmann; Michael Billion; Abbas Ferdosi; Marek Kowalski; Ehab Rajab; Karin Bramlage; Peter Bramlage; Henning Warnecke; Norbert Franz
Journal:  Open Heart       Date:  2020-02-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.