Literature DB >> 26384536

Development and evaluation of a digital dental modeling method based on grating projection and reverse engineering software.

Qin Zhou1, Zhenzhen Wang2, Jun Chen3, Jun Song2, Lu Chen2, Yi Lu4.   

Abstract

STATEMENT OF PROBLEM: For reasons of convenience and economy, attempts have been made to transform traditional dental gypsum casts into 3-dimensional (3D) digital casts. Different scanning devices have been developed to generate digital casts; however, each has its own limitations and disadvantages.
PURPOSE: The purpose of this study was to develop an advanced method for the 3D reproduction of dental casts by using a high-speed grating projection system and noncontact reverse engineering (RE) software and to evaluate the accuracy of the method.
MATERIAL AND METHODS: The methods consisted of 3 main steps: the scanning and acquisition of 3D dental cast data with a high-resolution grating projection system, the reconstruction and measurement of digital casts with RE software, and the evaluation of the accuracy of this method using 20 dental gypsum casts. The common anatomic landmarks were measured directly on the gypsum casts with a Vernier caliper and on the 3D digital casts with the Geomagic software measurement tool. Data were statistically assessed with the t test.
RESULTS: The grating projection system had a rapid scanning speed, and smooth 3D dental casts were obtained. The mean differences between the gypsum and 3D measurements were approximately 0.05 mm, and no statistically significant differences were found between the 2 methods (P>.05), except for the measurements of the incisor tooth width and maxillary arch length.
CONCLUSIONS: A method for the 3D reconstruction of dental casts was developed by using a grating projection system and RE software. The accuracy of the casts generated using the grating projection system was comparable with that of the gypsum casts.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2015        PMID: 26384536     DOI: 10.1016/j.prosdent.2015.06.016

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Three-dimensional evaluation of surgical techniques in neonates with orofacial cleft.

Authors:  Cleide Felício Carvalho Carrara; Eloá Cristina Passucci Ambrosio; Bianca Zeponi Fernandes Mello; Paula Karine Jorge; Simone Soares; Maria Aparecida Andrade Moreira Machado; Thais Marchini Oliveira
Journal:  Ann Maxillofac Surg       Date:  2016 Jul-Dec

2.  Evaluation of the effect of dentin surface treatment by air abrasion and Er:YAG laser on the retention of metal crowns luted with glass ionomer cement in teeth with reduced crown height: An in vitro study.

Authors:  Sameer Chauhan; Neerja Mahajan; Rajesh Sethuraman; Y G Naveen
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

3.  Case Report: Digital analysis of occlusion with T-Scan Novus in occlusal splint treatment for a patient with bruxism.

Authors:  Dobromira Shopova; Tanya Bozhkova; Svetlana Yordanova; Miroslava Yordanova
Journal:  F1000Res       Date:  2021-09-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.