Miniscrew implant fracture and effects of such retained tip on dentin-pulp complex: a histological report.

Valai Kasim Shakeel Ahmed1, Nathamuni Rengarajan Krishnaswamy1, Rooban Thavarajah2.   

Abstract

Miniscrew implants provide an excellent orthodontic anchorage. Besides the clinical benefits, miniscrew implants cause minor discomforts and in certain instances poses problematic complications. Damage to the adjacent tooth structure is the most feared complication of miniscrew implant placement, while fracture of miniscrew implants is the rarest. Miniscrew fracture could occur either during its placement or during its removal. An unusual case report is presented of a miniscrew implant tip fracture following root contact while attempting to remove it. This report highlights the effect of such miniscrew implant fracture on the dentin-pulp complex. The present case is probably the first to give direct histological evidence in humans that a miniscrew fracture or a retained miniscrew implant tip along the dentin/cementum without obvious miniscrew implant penetration could elicit pulp changes. Therefore this case report emphasizes the fact that prior to placing miniscrew implant, clinicians should have acquired proper training and adequate skills in terms of MSI placement and management of fractured MSI.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Miniscrew implant fracture; dentin-pulp complex; pulpal changes; vacuolization

Mesh:

Substances:

Year:  2015        PMID: 26382020     DOI: 10.1111/edt.12225

Source DB:  PubMed          Journal:  Dent Traumatol        ISSN: 1600-4469            Impact factor:   3.333


  3 in total

1.  Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs).

Authors:  Andrea Scribante; Mona A Montasser; Eman Saad Radwan; Luisa Bernardinelli; Roberto Alcozer; Paola Gandini; Maria Francesca Sfondrini
Journal:  Materials (Basel)       Date:  2018-07-05       Impact factor: 3.623

2.  Mechanical strength of stainless steel and titanium alloy mini-implants with different diameters: an experimental laboratory study.

Authors:  Sérgio Estelita Barros; Viviane Vanz; Kelly Chiqueto; Guilherme Janson; Eduardo Ferreira
Journal:  Prog Orthod       Date:  2021-03-22       Impact factor: 2.750

3.  Clinical effectiveness of orthodontic miniscrew implantation guided by a novel cone beam CT image-based computer aided design and computer aided manufacturing (CAD-CAM) template.

Authors:  Lingling Qiu; Hui Xu; Pingping Feng; Xiaoyan Sha; Hongwei Zhang
Journal:  Ann Transl Med       Date:  2021-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.