Literature DB >> 26379964

An ınvestigation into the in-vitro effectiveness of electrolyzed water against various microorganisms.

Keramettin Yanik1, Adil Karadag1, Nevzat Unal2, Hakan Odabasi1, Saban Esen3, Murat Gunaydin4.   

Abstract

The aim of this study was to investigate the in-vitro antimicrobial activity of usage and normal concentrations of electrolyzed water in hospital. In our study, the effects of different concentrations of electrolyzed water named Envirolyte® (Industries International Ltd., Estonia) on two gram positive, four gram negative standard strains and clinical isolates of four gram negative, two gram positive, one spore-forming bacillus and Myroides spp strains that lead to hospital infections were researched. The effects of different concentrations and different contact times of Envirolyte® electrolyzed water on cited strains were researched through method of qualitative suspension tests. Petri dishes fo bacteria have been incubated at 37°C 48 hours. Bactericidal disinfectant was interpreted to be effective at the end of the period due to the lack of growth. Solutions to which disinfectant were not added were prepared with an eye to control reproduction and controlcultures were made by using neutralizing agents. 1/1, 1/2, and 1/10 concentrations of Envirolyte® electrolyzed water were found to be effective on the bacteria that lead to hospital infections used during all test times. As a conclusion, based upon the results we acquired, it was observed that Envirolyte® electrolyzed water of 100% concentration would be convenient to be used for disinfection when diluted to a usage concentration of 1/10.

Entities:  

Keywords:  Electrolyzed water; bacteria; disinfectant

Year:  2015        PMID: 26379964      PMCID: PMC4565347     

Source DB:  PubMed          Journal:  Int J Clin Exp Med        ISSN: 1940-5901


  10 in total

1.  Sterilox disinfection of endoscopes.

Authors:  J B Selkon
Journal:  J Hosp Infect       Date:  2001-06       Impact factor: 3.926

2.  The bactericidal effects of electrolyzed oxidizing water on bacterial strains involved in hospital infections.

Authors:  Nina V Vorobjeva; Lena I Vorobjeva; Evgenij Y Khodjaev
Journal:  Artif Organs       Date:  2004-06       Impact factor: 3.094

3.  An investigation of the efficacy of super-oxidised (Optident/Sterilox) water for the disinfection of dental unit water lines.

Authors:  M V Martin; M A Gallagher
Journal:  Br Dent J       Date:  2005-03-26       Impact factor: 1.626

4.  Microcyn: a novel super-oxidized water with neutral pH and disinfectant activity.

Authors:  C Landa-Solis; D González-Espinosa; B Guzmán-Soriano; M Snyder; G Reyes-Terán; K Torres; A A Gutierrez
Journal:  J Hosp Infect       Date:  2005-10-19       Impact factor: 3.926

5.  Some factors influencing the stability of Sterilox(®), a super-oxidised water.

Authors:  G Rossi-Fedele; E J Dogramaci; L Steier; J A P de Figueiredo
Journal:  Br Dent J       Date:  2011-03-04       Impact factor: 1.626

Review 6.  Electrochemically activated solutions: evidence for antimicrobial efficacy and applications in healthcare environments.

Authors:  R M S Thorn; S W H Lee; G M Robinson; J Greenman; D M Reynolds
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-08-02       Impact factor: 3.267

7.  Inactivation of Escherichia coli, Listeria monocytogenes, Pseudomonas aeruginosa and Staphylococcus aureus on stainless steel and glass surfaces by neutral electrolysed water.

Authors:  M A Deza; M Araujo; M J Garrido
Journal:  Lett Appl Microbiol       Date:  2005       Impact factor: 2.858

8.  Effectiveness of electrolyzed oxidized water irrigation in a burn-wound infection model.

Authors:  H Nakae; H Inaba
Journal:  J Trauma       Date:  2000-09

9.  The use of electrolyzed solutions for the cleaning and disinfecting of dialyzers.

Authors:  N Tanaka; N Tanaka; T Fujisawa; T Daimon; K Fujiwara; M Yamamoto; T Abe
Journal:  Artif Organs       Date:  2000-12       Impact factor: 3.094

10.  In vitro antimicrobial activity of Medilox® super-oxidized water.

Authors:  Murat Gunaydin; Saban Esen; Adil Karadag; Nevzat Unal; Keramettin Yanik; Hakan Odabasi; Asuman Birinci
Journal:  Ann Clin Microbiol Antimicrob       Date:  2014-07-14       Impact factor: 3.944

  10 in total
  2 in total

1.  Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions.

Authors:  A S Mahalakshmi; Vidhya Jeyapalan; Vallabh Mahadevan; Chitra Shankar Krishnan; N S Azhagarasan; Hariharan Ramakrishnan
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

2.  Antiseptic Effects and Biosafety of a Controlled-Flow Electrolyzed Acid Solution Involve Electrochemical Properties, Rather than Free Radical Presence.

Authors:  Alejandro Cabrera-Wrooman; Silvestre Ortega-Peña; Rosa M Salgado; Belinda Sandoval-Cuevas; Edgar Krötzsch
Journal:  Microorganisms       Date:  2022-03-30
  2 in total