Literature DB >> 26371612

The Use of Digital Impressions to Fabricate Tooth-Supported Partial Removable Dental Prostheses: A Clinical Report.

Mohamed Mansour1, Eliana Sanchez1, Camilo Machado1.   

Abstract

Impression making is a critical step in the fabrication of a partial removable dental prosthesis (RDP). A technique is described for making final impressions to fabricate partial RDPs for Kennedy class III patients using a computer-aided design and computer-assisted manufacturing digital impression system.
© 2015 by the American College of Prosthodontists.

Entities:  

Keywords:  3D dental model; Digital impressions; LAVA COS; dental Scanner; removable partial denture

Mesh:

Year:  2015        PMID: 26371612     DOI: 10.1111/jopr.12346

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  6 in total

Review 1.  A Scoping Review on the Accuracy of Fit of Removable Partial Dentures in a Developing Digital Context.

Authors:  Noor Al Mortadi; Karem H Alzoubi; Robert Williams
Journal:  Clin Cosmet Investig Dent       Date:  2020-11-19

Review 2.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

3.  A New Concept for the Treatment and Rehabilitation of Patients with Pathologic Comorbidities Using Cutting-Edge Digital Technologies in Dental Orthopaedics.

Authors:  Alexey V Yumashev; Maria V Mikhailova; Igor V Fomin; Jiaqi Li; Bowen Yang
Journal:  Eur J Dent       Date:  2020-07-29

Review 4.  Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology.

Authors:  Khalid A O Arafa
Journal:  Saudi Med J       Date:  2018-01       Impact factor: 1.484

5.  Applying intraoral scanner to residual ridge in edentulous regions: in vitro evaluation of inter-operator validity to confirm trueness.

Authors:  Akinori Tasaka; Yuuki Uekubo; Tomoharu Mitsui; Takao Kasahara; Takuya Takanashi; Shinya Homma; Satoru Matsunaga; Shinichi Abe; Masao Yoshinari; Yasutomo Yajima; Kaoru Sakurai; Shuichiro Yamashita
Journal:  BMC Oral Health       Date:  2019-12-02       Impact factor: 2.757

6.  Complete-Arch Accuracy of Four Intraoral Scanners: An In Vitro Study.

Authors:  Giordano Celeghin; Giulio Franceschetti; Nicola Mobilio; Alberto Fasiol; Santo Catapano; Massimo Corsalini; Francesco Grande
Journal:  Healthcare (Basel)       Date:  2021-03-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.