Radiation-force-based estimation of acoustic attenuation using harmonic motion imaging (HMI) in phantoms and in vitro livers before and after HIFU ablation.

Jiangang Chen1, Gary Y Hou, Fabrice Marquet, Yang Han, Francisco Camarena, Elisa Konofagou.   

Abstract

Acoustic attenuation represents the energy loss of the propagating wave through biological tissues and plays a significant role in both therapeutic and diagnostic ultrasound applications. Estimation of acoustic attenuation remains challenging but critical for tissue characterization. In this study, an attenuation estimation approach was developed using the radiation-force-based method of harmonic motion imaging (HMI). 2D tissue displacement maps were acquired by moving the transducer in a raster-scan format. A linear regression model was applied on the logarithm of the HMI displacements at different depths in order to estimate the acoustic attenuation. Commercially available phantoms with known attenuations (n = 5) and in vitro canine livers (n = 3) were tested, as well as HIFU lesions in in vitro canine livers (n = 5). Results demonstrated that attenuations obtained from the phantoms showed a good correlation (R² = 0.976) with the independently obtained values reported by the manufacturer with an estimation error (compared to the values independently measured) varying within the range of 15-35%. The estimated attenuation in the in vitro canine livers was equal to 0.32   ±   0.03 dB cm(-1) MHz(-1), which is in good agreement with the existing literature. The attenuation in HIFU lesions was found to be higher (0.58   ±   0.06 dB cm(-1) MHz(-1)) than that in normal tissues, also in agreement with the results from previous publications. Future potential applications of the proposed method include estimation of attenuation in pathological tissues before and after thermal ablation.

Entities:  

Mesh:

Year:  2015        PMID: 26371501      PMCID: PMC4571197          DOI: 10.1088/0031-9155/60/19/7499

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  In vitro and in vivo ablation of porcine renal tissues using high-intensity focused ultrasound.

Authors:  Christakis Damianou
Journal:  Ultrasound Med Biol       Date:  2003-09       Impact factor: 2.998

2.  Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses.

Authors:  U Techavipoo; T Varghese; Q Chen; T A Stiles; J A Zagzebski; G R Frank
Journal:  J Acoust Soc Am       Date:  2004-06       Impact factor: 1.840

3.  An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy.

Authors:  Neeta Parmar; Michael C Kolios
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

4.  Characterizing acoustic attenuation of homogeneous media using focused impulsive acoustic radiation force.

Authors:  Mark L Palmeri; Kristin D Frinkley; Katherine G Oldenburg; Kathryn R Nightingale
Journal:  Ultrason Imaging       Date:  2006-04       Impact factor: 1.578

5.  Ultrasound attenuation measurement in the presence of scatterer variation for reduction of shadowing and enhancement.

Authors:  Graham Treece; Richard Prager; Andrew Gee
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

6.  Performance assessment of HIFU lesion detection by harmonic motion imaging for focused ultrasound (HMIFU): a 3-D finite-element-based framework with experimental validation.

Authors:  Gary Y Hou; Jianwen Luo; Fabrice Marquet; Caroline Maleke; Jonathan Vappou; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2011-10-27       Impact factor: 2.998

7.  Ultrasonic attenuation and absorption in liver tissue.

Authors:  K J Parker
Journal:  Ultrasound Med Biol       Date:  1983 Jul-Aug       Impact factor: 2.998

Review 8.  Attenuation estimation in reflection: progress and prospects.

Authors:  J Ophir; T H Shawker; N F Maklad; J G Miller; S W Flax; P A Narayana; J P Jones
Journal:  Ultrason Imaging       Date:  1984-10       Impact factor: 1.578

9.  Simulation study of amplitude-modulated (AM) harmonic motion imaging (HMI) for stiffness contrast quantification with experimental validation.

Authors:  Caroline Maleke; Jianwen Luo; Viktor Gamarnik; Xin L Lu; Elisa E Konofagou
Journal:  Ultrason Imaging       Date:  2010-07       Impact factor: 1.578

10.  Absorption and attenuation in soft tissues. II. Experimental results.

Authors:  M E Lyons; K J Parker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1988       Impact factor: 2.725

View more
  7 in total

1.  Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI).

Authors:  Thomas Payen; Carmine F Palermo; Stephen A Sastra; Hong Chen; Yang Han; Kenneth P Olive; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2016-07-12       Impact factor: 3.609

2.  High-intensity focused ultrasound monitoring using harmonic motion imaging for focused ultrasound (HMIFU) under boiling or slow denaturation conditions.

Authors:  Gary Y Hou; Fabrice Marquet; Shutao Wang; Iason-Zacharias Apostolakis; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

3.  Non-contact, ultrasound-based indentation method for measuring elastic properties of biological tissues using harmonic motion imaging (HMI).

Authors:  Jonathan Vappou; Gary Y Hou; Fabrice Marquet; Danial Shahmirzadi; Julien Grondin; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2015-03-17       Impact factor: 3.609

4.  Synchronous temperature variation monitoring during ultrasound imaging and/or treatment pulse application: a phantom study.

Authors:  Hermes A S Kamimura; Niloufar Saharkhiz; Stephen A Lee; Elisa E Konofagou
Journal:  IEEE Open J Ultrason Ferroelectr Freq Control       Date:  2021-06-03

5.  An analytical model of full-field displacement and strain induced by amplitude-modulated focused ultrasound in harmonic motion imaging.

Authors:  Matthew D J McGarry; Adriaan Campo; Thomas Payen; Yang Han; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2021-04-06       Impact factor: 3.609

6.  High-intensity focused ultrasound-triggered nanoscale bubble-generating liposomes for efficient and safe tumor ablation under photoacoustic imaging monitoring.

Authors:  Gang Feng; Lan Hao; Chunyan Xu; Haitao Ran; Yuanyi Zheng; Pan Li; Yang Cao; Qi Wang; Jizhu Xia; Zhigang Wang
Journal:  Int J Nanomedicine       Date:  2017-06-28

Review 7.  Acoustic Radiation Force Based Ultrasound Elasticity Imaging for Biomedical Applications.

Authors:  Lulu Wang
Journal:  Sensors (Basel)       Date:  2018-07-12       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.