Literature DB >> 26370904

Influence of implant neck design on facial bone crest dimensions in the esthetic zone analyzed by cone beam CT: a comparative study with a 5-to-9-year follow-up.

Vivianne Chappuis1, Michael M Bornstein1, Daniel Buser1, Urs Belser2.   

Abstract

AIM: To examine the influence of two different neck designs on facial bone crest dimensions in esthetic single implant sites after a 5-to-9-year follow-up analyzed by cone beam computed tomography (CBCT).
MATERIALS AND METHODS: Sixty-one patients with an implant-borne single crown following early implant placement in the esthetic zone were enrolled. The test group consisted of a bone level (BL) neck design exhibiting a hydrophilic micro-rough surface combined with a platform-switching interface (PS) (n = 20). The control group comprised a soft tissue level (STL) neck design exhibiting a hydrophobic machined surface with a matching butt-joint interface (n = 41). Standardized clinical, radiologic, and esthetic parameters were applied. The facial bone crest dimensions were assessed by CBCT.
RESULTS: Soft tissue parameters and pink esthetic scores yielded no significant differences between the two designs. Major differences were only observed at the implant shoulder level. The height of the facial bone crest for the BL design was located 0.2 mm above the implant shoulder level, whereas for the STL design, its location was 1.6 mm below. The width of the peri-implant saucer-like bone defect was reduced by 40% for the BL implant design. No differences were observed 2 mm below the shoulder level.
CONCLUSIONS: The results of this comparative study suggest better crestal bone stability on the facial aspect of single implant sites in the esthetic zone for a BL design with a platform-switching concept when compared with STL implants with a butt-joint interface.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone loss; bone regeneration; bone remodeling; bone resorption; cone beam computed tomography; dental implant-abutment design; dental implants

Mesh:

Year:  2015        PMID: 26370904     DOI: 10.1111/clr.12692

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

Review 1.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

2.  The depth of the implant mucosal tunnel modifies the development and resolution of experimental peri-implant mucositis: A case-control study.

Authors:  Dave Chan; George Pelekos; Dominic Ho; Pierpaolo Cortellini; Maurizio S Tonetti
Journal:  J Clin Periodontol       Date:  2019-02-07       Impact factor: 8.728

3.  Facial alveolar bone thickness and modifying factors of anterior maxillary teeth: a systematic review and meta-analysis of cone-beam computed tomography studies.

Authors:  Julio Rojo-Sanchis; David Soto-Peñaloza; David Peñarrocha-Oltra; Miguel Peñarrocha-Diago; José Viña-Almunia
Journal:  BMC Oral Health       Date:  2021-03-22       Impact factor: 2.757

Review 4.  Effect of laser-microtexturing on bone and soft tissue attachments to dental implants: A systematic review and meta-analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

5.  Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review.

Authors:  Saverio Cosola; Simone Marconcini; Michela Boccuzzi; Giovanni Battista Menchini Fabris; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Int J Environ Res Public Health       Date:  2020-09-22       Impact factor: 3.390

  5 in total