Literature DB >> 26368682

Performance of a dual Fabry-Perot cavity refractometer.

Patrick F Egan, Jack A Stone, Jay H Hendricks, Jacob E Ricker, Gregory E Scace, Gregory F Strouse.   

Abstract

We have built and characterized a refractometer that utilizes two Fabry-Perot cavities formed on a dimensionally stable spacer. In the typical mode of operation, one cavity is held at vacuum, and the other cavity is filled with nitrogen gas. The differential change in length between the cavities is measured as the difference in frequency between two helium-neon lasers, one locked to the resonance of each cavity. This differential change in optical length is a measure of the gas refractivity. Using the known values for the molar refractivity and virial coefficients of nitrogen, and accounting for cavity length distortions, the device can be used as a high-resolution, multi-decade pressure sensor. We define a reference value for nitrogen refractivity as n-1=(26485.28±0.3)×10(-8) at p=100.0000  kPa, T=302.9190  K, and λ(vac)=632.9908  nm. We compare pressure determinations via the refractometer and the reference value to a mercury manometer.

Entities:  

Year:  2015        PMID: 26368682     DOI: 10.1364/OL.40.003945

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  7 in total

1.  Measured relationship between thermodynamic pressure and refractivity for six candidate gases in laser barometry.

Authors:  Patrick F Egan; Jack A Stone; Julia K Scherschligt; Allan H Harvey
Journal:  J Vac Sci Technol A       Date:  2019       Impact factor: 2.427

2.  Quantum for pressure.

Authors:  Jay Hendricks
Journal:  Nat Phys       Date:  2018       Impact factor: 20.034

3.  Towards Traceable Transient Pressure Metrology.

Authors:  Edward Hanson; Douglas Olson; Haijun Liu; Zeeshan Ahmed; Kevin O Douglass
Journal:  Metrologia       Date:  2018-03-13       Impact factor: 3.157

4.  Transient heating in fixed length optical cavities for use as temperature and pressure standards.

Authors:  J Ricker; K O Douglass; S Syssoev; J Stone; S Avdiaj; J H Hendricks
Journal:  Metrologia       Date:  2021       Impact factor: 3.157

5.  Comparison measurements of low-pressure between a laser refractometer and ultrasonic manometer.

Authors:  Patrick F Egan; Jack A Stone; Jacob E Ricker; Jay H Hendricks
Journal:  Rev Sci Instrum       Date:  2016-05       Impact factor: 1.523

6.  Investigation of optical force on magnetic nanoparticles with magnetic-fluid-filled Fabry-Perot interferometer.

Authors:  Tianjun Yao; Shengli Pu; Jie Rao; Jianming Zhang
Journal:  Sci Rep       Date:  2018-08-17       Impact factor: 4.379

7.  Towards Photonic based Pascal Realization as a Primary Pressure Standard.

Authors:  J Ricker; J Hendricks; P Egan; J Stone; K Douglass; G Scace
Journal:  J Phys Conf Ser       Date:  2018
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.