Literature DB >> 26365469

Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods.

R Buendia1, F Seoane, K Lindecrantz, I Bosaeus, R Gil-Pita, G Johannsson, L Ellegård, L C Ward.   

Abstract

Determination of body fluids is a useful common practice in determination of disease mechanisms and treatments. Bioimpedance spectroscopy (BIS) methods are non-invasive, inexpensive and rapid alternatives to reference methods such as tracer dilution. However, they are indirect and their robustness and validity are unclear. In this article, state of the art methods are reviewed, their drawbacks identified and new methods are proposed. All methods were tested on a clinical database of patients receiving growth hormone replacement therapy. Results indicated that most BIS methods are similarly accurate (e.g.  <  0.5 ±   3.0% mean percentage difference for total body water) for estimation of body fluids. A new model for calculation is proposed that performs equally well for all fluid compartments (total body water, extra- and intracellular water). It is suggested that the main source of error in extracellular water estimation is due to anisotropy, in total body water estimation to the uncertainty associated with intracellular resistivity and in determination of intracellular water a combination of both.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26365469     DOI: 10.1088/0967-3334/36/10/2171

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

Review 1.  Fluid balance concepts in medicine: Principles and practice.

Authors:  Maria-Eleni Roumelioti; Robert H Glew; Zeid J Khitan; Helbert Rondon-Berrios; Christos P Argyropoulos; Deepak Malhotra; Dominic S Raj; Emmanuel I Agaba; Mark Rohrscheib; Glen H Murata; Joseph I Shapiro; Antonios H Tzamaloukas
Journal:  World J Nephrol       Date:  2018-01-06

2.  Proposal of a Lab Bench for the Unobtrusive Monitoring of the Bladder Fullness with Bioimpedance Measurements.

Authors:  Valentin Gaubert; Hayriye Gidik; Vladan Koncar
Journal:  Sensors (Basel)       Date:  2020-07-17       Impact factor: 3.576

3.  Segmental Bioimpedance Analysis as a Predictor of Injury and Performance Status in Professional Basketball Players: A New Application Potential?

Authors:  Alexander Bertuccioli; Marco Cardinali; Piero Benelli
Journal:  Life (Basel)       Date:  2022-07-15

Review 4.  Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis.

Authors:  Jung Hwan Park; Young-Il Jo; Jong-Ho Lee
Journal:  Korean J Intern Med       Date:  2018-06-28       Impact factor: 2.884

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.