Literature DB >> 26365343

An 8 minute colorimetric paper-based reverse phase vertical flow serum microarray for screening of hyper IgE syndrome.

Philippa Reuterswärd1, Jesper Gantelius, Helene Andersson Svahn.   

Abstract

Reverse phase microarrays are useful tools for affinity-based detection in hundreds of samples simultaneously. However, current methods typically require long assay times and fluorescent detection. Here we describe a paper-based Vertical Flow Microarray (VFM) assay as a rapid 8-minute colorimetric alternative for reverse phase microarray analysis. The VFM platform was optimized for detection of IgE with a detection limit of 1.9 μg mL(-1) in whole serum. Optimized conditions were then used to screen 113 serum samples simultaneously for hyper IgE syndrome (hIgE), a rare primary immunodeficiency characterized by elevated levels of IgE. The same set of samples were then analysed with a conventional planar microarray with fluorescent detection for head-to-head testing. Both assays found elevated levels in three out of four hIgE patient samples, whereas no control samples displayed elevated levels in either method. The comparison experiments showed a good correlation between the two assays, as determined from a linear correlation study (Pearson's r = 0.76). Further, the assay-time reduction and reproducibility (intra assay CV = 12.4 ± 4.11%) demonstrate the applicability of the VFM platform for high throughput reverse phase screening.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26365343     DOI: 10.1039/c5an01013f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  A vertical flow microarray chip based on SERS nanotags for rapid and ultrasensitive quantification of α-fetoprotein and carcinoembryonic antigen.

Authors:  Di Zhang; Li Huang; Bing Liu; Qinyu Ge; Jian Dong; Xiangwei Zhao
Journal:  Mikrochim Acta       Date:  2019-10-15       Impact factor: 5.833

Review 2.  Design of Gold Nanoparticle Vertical Flow Assays for Point-of-Care Testing.

Authors:  Rongwei Lei; David Wang; Hufsa Arain; Chandra Mohan
Journal:  Diagnostics (Basel)       Date:  2022-04-28

3.  A Critical Comparison between Flow-through and Lateral Flow Immunoassay Formats for Visual and Smartphone-Based Multiplex Allergen Detection.

Authors:  Georgina M S Ross; Gert Ij Salentijn; Michel W F Nielen
Journal:  Biosensors (Basel)       Date:  2019-12-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.