Determination of trace mercury in water based on N-octylpyridinium ionic liquids preconcentration and stripping voltammetry.

Zhenhan Li1, Shanhong Xia2, Jinfen Wang1, Chao Bian1, Jianhua Tong1.   

Abstract

A novel method for determination of trace mercury in water is developed. The method is performed by extracting mercury firstly with ionic liquids (ILs) and then detecting the concentration of mercury in organic media with anodic stripping voltammetry. Liquid-liquid extraction of mercury(II) ions by four ionic liquids with N-octylpyridinium cations ([OPy](+)) was studied. N-octylpyridinium tetrafluoroborate and N-octylpyridinium trifluoromethylsulfonate were found to be efficient and selective extractant for mercury. Temperature controlled dispersive liquid phase microextraction (TC-DLPME) technique was utilized to improve the performance of preconcentration. After extraction, precipitated IL was diluted by acetonitrile buffer and mercury was detected by differential pulse stripping voltammetry (DPSV) with gold disc electrode. Mercury was enriched by 17 times while interfering ions were reduced by two orders of magnitude in the organic media under optimum condition. Sensitivity and selectivity for electrochemical determination of mercury were improved by using the proposed method. Tap, pond and waste water samples were analyzed with recoveries ranging from 81% to 107% and detection limit of 0.05 μg/L.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anodic stripping voltammetry; Ionic liquid; Mercury determination; Preconcentration

Mesh:

Substances:

Year:  2015        PMID: 26364269     DOI: 10.1016/j.jhazmat.2015.08.061

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  7 in total

1.  Comparison of Two Types of Overoxidized PEDOT Films and Their Application in Sensor Fabrication.

Authors:  Yun Hui; Chao Bian; Jinfen Wang; Jianhua Tong; Shanhong Xia
Journal:  Sensors (Basel)       Date:  2017-03-19       Impact factor: 3.576

2.  Determination of Mercury(II) on A Centrifugal Microfluidic Device Using Ionic Liquid Dispersive Liquid-Liquid Microextraction.

Authors:  Yun Hui; Yujia Liu; William C Tang; Dian Song; Marc Madou; Shanhong Xia; Tianzhun Wu
Journal:  Micromachines (Basel)       Date:  2019-08-08       Impact factor: 2.891

3.  Synthesis and Characterization of Ru-MOFs on Microelectrode for Trace Mercury Detection.

Authors:  Chenyu Xiong; Yuhao Xu; Chao Bian; Ri Wang; Yong Xie; Mingjie Han; Shanhong Xia
Journal:  Sensors (Basel)       Date:  2020-11-23       Impact factor: 3.576

4.  Electrochemical measurements and theoretical studies for understanding the behavior of catechol, resorcinol and hydroquinone on the boron doped diamond surface.

Authors:  Amison Rick Lopes da Silva; Alexsandro Jhones Dos Santos; Carlos Alberto Martínez-Huitle
Journal:  RSC Adv       Date:  2018-01-16       Impact factor: 3.361

Review 5.  Recent Studies on the Speciation and Determination of Mercury in Different Environmental Matrices Using Various Analytical Techniques.

Authors:  Lakshmi Narayana Suvarapu; Sung-Ok Baek
Journal:  Int J Anal Chem       Date:  2017-11-20       Impact factor: 1.885

6.  Quantitative Determining of Ultra-Trace Aluminum Ion in Environmental Samples by Liquid Phase Microextraction Assisted Anodic Stripping Voltammetry.

Authors:  Liuyang Zhang; Jinju Luo; Xinyu Shen; Chunya Li; Xian Wang; Bei Nie; Huaifang Fang
Journal:  Sensors (Basel)       Date:  2018-05-10       Impact factor: 3.576

7.  [OPy][BF4] Selective Extraction for Trace Hg2+ Detection by Electrochemistry: Enrichment, Release and Sensing.

Authors:  Chenyu Xiong; Yun Hui; Ri Wang; Chao Bian; Yuhao Xu; Yong Xie; Mingjie Han; Shanhong Xia
Journal:  Micromachines (Basel)       Date:  2021-11-27       Impact factor: 2.891

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.