Patent ductus arteriosus occlusion in small dogs utilizing a low profile Amplatz® canine duct occluder prototype.

Christopher D Stauthammer1, Janet Olson2, Damon Leeder2, Kristin Hohnadel2, Melissa Hanson2, Anthony H Tobias2.   

Abstract

OBJECTIVES: To develop procedural methodology and assess the safety, utility and effectiveness of a low profile Amplatz(®) canine duct occluder (ACDO) prototype in dogs deemed too small to undergo ductal occlusion with the commercially-available ACDO device. ANIMALS: Twenty-one dogs with left-to-right shunting patent ductus arteriosus (PDA). Dogs were ≥1.5 kg but considered too small to accommodate a 6 Fr catheter or 4 Fr sheath within the femoral artery.
METHODS: Prospective canine study using a low profile ACDO prototype delivered through a 4 Fr catheter via a femoral arterial approach. Procedural methods, fluoroscopy time, perioperative complications, and residual ductal flow were evaluated, and angiographic ductal morphology and dimensions were tabulated.
RESULTS: All 21 dogs underwent successful ductal occlusion using the prototype device, 4 Fr catheter, and right femoral artery approach. No perioperative complications or device embolization occurred. The median minimal ductal diameter was 1.9 mm (range, 0.4-3.4), and the median device size deployed was 4 mm (range, 3-6). Complete ductal occlusion was noted in 17 dogs (81%) on post-deployment angiography. Twenty dogs (95%) had no residual flow on echocardiography performed the following day. In the 17 dogs (81%) that returned for a long-term (≥3months) follow-up evaluation, all had complete ductal occlusion based on echocardiography.
CONCLUSIONS: The low profile ACDO prototype is a safe and effective method of PDA occlusion in the small dog. The deployment procedure appears of similar technical difficulty to the commercially available ACDO.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Angiography; Cardiac catheterization; Congenital; Intervention

Mesh:

Year:  2015        PMID: 26363940     DOI: 10.1016/j.jvc.2015.06.002

Source DB:  PubMed          Journal:  J Vet Cardiol        ISSN: 1760-2734            Impact factor:   1.701


  4 in total

1.  An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

Authors:  Mark A Wierzbicki; Sarah B Raines; Sonya G Gordon; John C Criscione; Ashley B Saunders; Scott Birch; Bradley Due; Brandis Keller; Landon D Nash; Matthew W Miller; Duncan J Maitland
Journal:  J Mech Behav Biomed Mater       Date:  2017-07-25

2.  Late recanalization after complete occlusion of patent ductus arteriosus in a Pembroke Welsh Corgi with von Willebrand disease.

Authors:  Masaki Kochi; Keisuke Sugimoto; Michito Inoue; Takuma Aoki
Journal:  Vet Med Sci       Date:  2021-09-19

3.  Transvenous embolization of moderate to large patent ductus arteriosus in dogs using the Amplatzer vascular plug II.

Authors:  Nicolai Hildebrandt; Andreas Stosic; Estelle Henrich; Nicola Wiedemann; Gabriel Wurtinger; Matthias Schneider
Journal:  J Vet Intern Med       Date:  2021-12-16       Impact factor: 3.333

4.  Low profile vascular plug for transarterial occlusion of patent ductus arteriosus in small dogs.

Authors:  Alma H Hulsman; Johannes M P J Breur; Viktor Szatmári
Journal:  J Vet Intern Med       Date:  2020-11-26       Impact factor: 3.175

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.