In vivo monitoring of the inflammatory response in a stented mouse aorta model.

Konstantinos K Kapnisis1, Costas M Pitsillides1, Marianna S Prokopi2, George Lapathitis3, Christos Karaiskos3, Polyvios C Eleftheriou1, Brigitta C Brott4, Peter G Anderson5, Jack E Lemons6, Andreas S Anayiotos1.   

Abstract

The popularity of vascular stents continues to increase for a variety of applications, including coronary, lower limb, renal, carotid, and neurovascular disorders. However, their clinical effectiveness is hindered by numerous postdeployment complications, which may stimulate inflammatory and fibrotic reactions. The purpose of this study was to evaluate the vessel inflammatory response via in vivo imaging in a mouse stent implantation model. Corroded and noncorroded self-expanding miniature nitinol stents were implanted in mice abdominal aortas, and novel in vivo imaging techniques were used to assess trafficking and accumulation of fluorescent donor monocytes as well as cellular proliferation at the implantation site. Monocytes were quantitatively tracked in vivo and found to rapidly clear from circulation within hours after injection. Differences were found between the test groups with respect to the numbers of recruited monocytes and the intensity of the resulting fluorescent signal. Image analysis also revealed a subtle increase in matrix metalloproteinase activity in corroded compared with the normal stented aortas. In conclusion, this study has been successful in developing a murine stent inflammation model and applying novel in vivo imaging tools and methods to monitor the complex biological processes of the host vascular wall response.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  in vivo imaging; inflammation; mouse stent model; stent corrosion

Mesh:

Substances:

Year:  2015        PMID: 26362825     DOI: 10.1002/jbm.a.35560

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  2 in total

1.  Effect of wire fretting on the corrosion resistance of common medical alloys.

Authors:  Danyal A Siddiqui; Shiril Sivan; Jason D Weaver; Matthew Di Prima
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-09-23       Impact factor: 3.368

2.  The effects of stenting on hemorheological parameters: An in vitro investigation under various blood flow conditions.

Authors:  K Kapnisis; H Seidner; M Prokopi; D Pasias; C Pitsillides; A Anayiotos; E Kaliviotis
Journal:  Clin Hemorheol Microcirc       Date:  2019       Impact factor: 2.375

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.