Potential risk of excising the femoral insertion of the popliteus tendon during primary total knee arthroplasty: a biometric study.

Atsushi Takahashi1, Takehiko Sugita2, Toshimi Aizawa3, Daisuke Chiba3, Masayuki Kamimura3, Takashi Aki3, Eiji Itoi3.   

Abstract

BACKGROUND: During total knee arthroplasty (TKA), excision of the popliteus tendon leads to extensive static gaps and reduced mobility. The purpose of this study was to determine the positional relationship between the femoral insertion of the popliteus tendon and the bone cutting lines of various TKA systems.
METHODS: This study included 21 cadaveric right femurs presenting no macroscopic deformity. The lateral image of the femur and the template of the femoral component were overlaid to determine the preservation/excision of the popliteus tendon insertion. TKA systems used were Genesis II, NexGen, low contact stress (LCS), PFC Σ, Scorpio, and Vanguard. The knees in which the insertion was preserved in all implants or excised in at least one implant were classified into intact or the high-risk groups, respectively.
RESULTS: The popliteus tendon was preserved in all specimens with the LCS system. In contrast, the popliteus tendon insertion was excised in ≥1/3 of the specimens with the other systems. The anteroposterior diameter was significantly larger in the intact group than that in the high-risk group (58.1 ± 4.5 mm vs. 53.7 ± 2.7 mm; p = 0.018). The high-risk group included more knees from female cadavers than the intact group (70 vs. 9 %; p = 0.008).
CONCLUSION: During primary TKA, the femoral insertion of the popliteus tendon could be inevitably excised, regardless of technical problems. We demonstrate that the unique design of the LCS system preserves the popliteus tendon insertion. In addition, small knees and females may be risk factors for excision of the insertion.

Entities:  

Mesh:

Year:  2015        PMID: 26362655     DOI: 10.1007/s00776-015-0773-x

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  2 in total

1.  Femoral footprint of the popliteus tendon may be at the risk of damage during total knee arthroplasty.

Authors:  Takashi Aki; Takehiko Sugita; Atsushi Takahashi; Toshimi Aizawa; Masayuki Kamimura; Akira Sasaki; Naohisa Miyatake; Eiji Itoi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-25       Impact factor: 4.342

2.  The evaluation of the distance between the popliteus tendon and the lateral collateral ligament footprint and the implant in Total knee Arthroplasty using a 3-dimensional template.

Authors:  Akihito Takubo; Keinosuke Ryu; Takanori Iriuchishima; Masahiro Nagaoka; Yasuaki Tokuhashi; Shin Aizawa
Journal:  BMC Musculoskelet Disord       Date:  2020-05-22       Impact factor: 2.362