Literature DB >> 26357698

Eleven-Year Retrospective Survival Study of 275 Veneered Lithium Disilicate Single Crowns.

Piero Simeone, Stefano Gracis.   

Abstract

The aim of the present clinical retrospective study was to evaluate the long-term survival and clinical performance of veneered lithium disilicate single restorations in anterior and posterior areas after up to 11 years. Following a rigid protocol, 275 lithium disilicate single crowns (35 IPS Empress II and 240 e.max Press) were cemented over 11 years, in 106 patients, using an adhesive technique; of these 106 were anterior (38.5%) and 169 posterior (61.5%) teeth. Teeth receiving endodontic therapy and composite reconstruction (50%) and teeth with preexisting metalceramic crowns, called prosthetic retreatments (PR; 65%), were included as well. Of the 106 patients enrolled in the study, 25 (23.5%) were diagnosed with bruxism habits, and 7 of these patients (6.6% of all patients) received full-mouth single lithium disilicate restorations (FMR). The exclusion criteria for this retrospective clinical study were: monolithic lithium disilicate crowns, teeth with cast post and cores, implant-supported all-ceramic crowns, active periodontitis, and/or poor oral hygiene. Clinical reevaluation was performed by the clinicians who prepared and luted them during maintenance appointments between January 2012 and October 2013. Number of restoration failures and characteristics of failures were recorded. Marginal adaptation and marginal discoloration were evaluated based on the Cvar-Ryge criteria. The overall cumulative survival rate was 98.2%. The failures recorded were the result of either mechanical failure or debonding. Five crowns failed mechanically-three because of chipping and two because of core fracture-and were replaced. None of the failed crowns was associated with the bruxers with FMR. A total of 15 crowns debonded (5.5% of all crowns); however, 11 belonged to the same patient who had endodontically treated and reconstructed abutments. In this retrospective clinical evaluation of up to 132 months, veneered lithium disilicate single crowns had a low failure rate.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26357698     DOI: 10.11607/prd.2150

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  8 in total

1.  Can lithium disilicate ceramic crowns be fabricated on the basis of CBCT data?

Authors:  Ana Elisa Colle Kauling; Christine Keul; Kurt Erdelt; Jan Kühnisch; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-02-06       Impact factor: 3.573

2.  Lithium disilicate posterior overlays: clinical and biomechanical features.

Authors:  Malchiodi Luciano; Zotti Francesca; Savoia Michela; Moro Tommaso; Albanese Massimo
Journal:  Clin Oral Investig       Date:  2019-06-14       Impact factor: 3.573

3.  Clinical survival of chair-side generated monolithic lithium disilicate crowns:10-year results.

Authors:  Angelika Rauch; Sven Reich; Luise Dalchau; Oliver Schierz
Journal:  Clin Oral Investig       Date:  2017-11-04       Impact factor: 3.573

Review 4.  "Digitally Oriented Materials": Focus on Lithium Disilicate Ceramics.

Authors:  Fernando Zarone; Marco Ferrari; Francesco Guido Mangano; Renato Leone; Roberto Sorrentino
Journal:  Int J Dent       Date:  2016-08-18

5.  IPS e.max for All-Ceramic Restorations: Clinical Survival and Success Rates of Full-Coverage Crowns and Fixed Partial Dentures.

Authors:  Silvia Brandt; Anna Winter; Hans-Christoph Lauer; Fritz Kollmar; Soo-Jeong Portscher-Kim; Georgios E Romanos
Journal:  Materials (Basel)       Date:  2019-02-02       Impact factor: 3.623

6.  Shear bond strength of debonded ceramic restorations re-cemented by means of a cleaning and retreatment protocol.

Authors:  Luisa Pineda-Vásquez; Antonio Fons-Font; Jose-Luis Bustos-Salvador; Jorge Alonso-Pérez-Barquero; Juan-Luis Román-Rodríguez
Journal:  J Clin Exp Dent       Date:  2019-06-01

Review 7.  Current status on lithium disilicate and zirconia: a narrative review.

Authors:  Fernando Zarone; Maria Irene Di Mauro; Pietro Ausiello; Gennaro Ruggiero; Roberto Sorrentino
Journal:  BMC Oral Health       Date:  2019-07-04       Impact factor: 2.757

8.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13
  8 in total