Influence of alginate impression materials and storage time on surface detail reproduction and dimensional accuracy of stone models.

Ricardo D Guiraldo1, Ana F F Moreti1, Julia Martinelli1, Sandrine B Berger1, Luciana L Meneghel1, Rodrigo V Caixeta1, Mário A C Sinhoreti2.   

Abstract

This study compared the surface detail reproduction and dimensional accuracy of stone models obtained from molds prepared using different alginate impression materials (Cavex ColorChange, Hydrogum 5, or Jeltrate Plus) and with different storage times (1, 3, and 5 days) to models from molds that were filled immediately with no storage time. The molds were prepared over a matrix containing 50-μm line, (ISO 1563 standard) under pressure with a perforated metal tray. The molds were removed 2 minutes after loss of sticky consistency and either filled immediately or stored in closed jars at 100% relative humidity and 37°C for 1, 3, or 5 days. The molds were filled with dental plaster (Durone IV). Surface detail reproduction and dimensional accuracy were evaluated using optical microscopy on the 50-μm wide line, which was 25 mm in length, according to ISO 1563 standard. The dimensional accuracy results (%) were subjected to analysis of variance. The 50-μm wide line (ISO 1563 standard) was completely reproduced by all alginate impression materials regardless of the storage time. There was no statistically significant difference in the mean dimensional accuracy values of stone models made from molds composed of different alginate impression materials and with different storage times (p = 0.989). In conclusion, storing the mold for five days prior to filling did not change the surface detail reproduction or dimensional accuracy of the alginates examined in this study.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26355886     DOI: 10.1590/S1852-48342015000200010

Source DB:  PubMed          Journal:  Acta Odontol Latinoam        ISSN: 0326-4815


  2 in total

1.  Surface Detail Reproduction and Dimensional Stability of Contemporary Irreversible Hydrocolloid Alternatives after Immediate and Delayed Pouring.

Authors:  Preethi Kusugal; Ritu Sunil Chourasiya; Zarir Ruttonji; Preeti Astagi; Ajay Kumar Nayak; Abhishekha Patil
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

2.  Influence of chloramine-T disinfection on elastomeric impression stability.

Authors:  Ricardo Danil Guiraldo; Sandrine Bittencourt Berger; Marilia Franco Punhagui; Thais Staut Moretto; Murilo Baena Lopes; Alcides Gonini-Júnior; Mário Alexandre Coelho Sinhoreti
Journal:  Eur J Dent       Date:  2018 Apr-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.