Literature DB >> 26355715

The Reliability of Strength Tests Performed In Elevated Shoulder Positions Using a Handheld Dynamometer.

Sally J McLaine1, Karen A Ginn, Cecilia M Kitic, James W Fell, Marie-Louise Bird.   

Abstract

CONTEXT: The reliable measurement of shoulder strength is important when assessing athletes involved in overhead activities. Swimmers' shoulders are subject to repetitive humeral elevation and consequently have a high risk of developing movement-control issues and pain. Shoulder-strength tests performed in positions of elevation assist with the detection of strength deficits that may affect injury and performance. The reliability of isometric strength tests performed in positions of humeral elevation without manual stabilization, which is a typical clinical scenario, has not been established.
OBJECTIVE: To establish the relative and absolute intrarater reliability of shoulder-strength tests functional to swimming in 3 body positions commonly used in the clinical setting.
DESIGN: Repeated-measures reliability study.
SETTING: Research laboratory.
SUBJECTS: 15 university students and staff (mean ± SD age 24 ± 8.2 y). INTERVENTION: Isometric shoulder-strength tests were performed in positions of humeral elevation (flexion and extension in 140° abduction in the scapular plane, internal and external rotation in 90° abduction) on subjects without shoulder pain in supine, prone, and sitting. Subjects were tested by 1 examiner with a handheld dynamometer and retested after 48 h. MAIN OUTCOME MEASURES: Relative reliability (ICC3,1) values with 95% CI. Absolute reliability was reported by minimal detectable change (MDC).
RESULTS: Good to excellent intrarater reliability was found for all shoulder-strength tests (ICC .87-.99). Intrarater reliability was not affected by body position. MDC% was <16% for every test and ≤11% for tests performed in supine.
CONCLUSIONS: Shoulder flexion, extension, and internal- and external-rotation strength tests performed in humeral elevation demonstrated excellent to good intrarater reliability regardless of body position. A strength change of more than 15% in any position can be considered meaningful.

Entities:  

Keywords:  isometric contraction; muscle-strength dynamometer; shoulder joint

Mesh:

Year:  2016        PMID: 26355715     DOI: 10.1123/jsr.2015-0034

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  5 in total

1.  Function, strength, and muscle activation of the shoulder complex in Crossfit practitioners with and without pain: a cross-sectional observational study.

Authors:  Elisa Raulino Silva; Nicola Maffulli; Filippo Migliorini; Gilmar Moraes Santos; Fábio Sprada de Menezes; Rodrigo Okubo
Journal:  J Orthop Surg Res       Date:  2022-01-15       Impact factor: 2.359

2.  Interrater and Intrarater Reliability of the EasyForce Dynamometer for Assessment of Maximal Shoulder, Knee and Hip Strength.

Authors:  Nebojša Trajković; Žiga Kozinc; Darjan Smajla; Nejc Šarabon
Journal:  Diagnostics (Basel)       Date:  2022-02-09

3.  Shoulder-specific rehabilitation combined with aerobic exercises versus solely shoulder-specific rehabilitation in patients with type 2 diabetes mellitus: study protocol for a randomized controlled superiority trial.

Authors:  Fernanda A P Habechian; Mauricio E Flores Quezada; Ann M Cools; Birgitte Hougs Kjaer; Rodrigo I Cuevas Cid; Gisele G Zanca
Journal:  Trials       Date:  2022-08-17       Impact factor: 2.728

4.  Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity.

Authors:  Dario Martinez-Garcia; Angela Rodriguez-Perea; Paola Barboza; David Ulloa-Díaz; Daniel Jerez-Mayorga; Ignacio Chirosa; Luis Javier Chirosa Ríos
Journal:  PeerJ       Date:  2020-10-27       Impact factor: 2.984

5.  Submaximal Elastic Resistance Band Tests to Estimate Upper and Lower Extremity Maximal Muscle Strength.

Authors:  Bjarki T Haraldsson; Christoffer H Andersen; Katrine T Erhardsen; Mette K Zebis; Jéssica K Micheletti; Carlos M Pastre; Lars L Andersen
Journal:  Int J Environ Res Public Health       Date:  2021-03-09       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.