Optimization of tissue physical parameters for accurate temperature estimation from finite-element simulation of radiofrequency ablation.

Swetha Subramanian1, T Douglas Mast.   

Abstract

Computational finite element models are commonly used for the simulation of radiofrequency ablation (RFA) treatments. However, the accuracy of these simulations is limited by the lack of precise knowledge of tissue parameters. In this technical note, an inverse solver based on the unscented Kalman filter (UKF) is proposed to optimize values for specific heat, thermal conductivity, and electrical conductivity resulting in accurately simulated temperature elevations. A total of 15 RFA treatments were performed on ex vivo bovine liver tissue. For each RFA treatment, 15 finite-element simulations were performed using a set of deterministically chosen tissue parameters to estimate the mean and variance of the resulting tissue ablation. The UKF was implemented as an inverse solver to recover the specific heat, thermal conductivity, and electrical conductivity corresponding to the measured area of the ablated tissue region, as determined from gross tissue histology. These tissue parameters were then employed in the finite element model to simulate the position- and time-dependent tissue temperature. Results show good agreement between simulated and measured temperature.

Entities:  

Mesh:

Year:  2015        PMID: 26352462      PMCID: PMC4609304          DOI: 10.1088/0031-9155/60/19/N345

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  Quantifying tissue damage due to focused ultrasound heating observed by MRI.

Authors:  S J Graham; L Chen; M Leitch; R D Peters; M J Bronskill; F S Foster; R M Henkelman; D B Plewes
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

2.  Thermal--electrical finite element modelling for radio frequency cardiac ablation: effects of changes in myocardial properties.

Authors:  S Tungjitkusolmun; E J Woo; H Cao; J Z Tsai; V R Vorperian; J G Webster
Journal:  Med Biol Eng Comput       Date:  2000-09       Impact factor: 2.602

3.  Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes.

Authors:  Dieter Haemmerich; Fred T Lee; David J Schutt; Lisa A Sampson; John G Webster; Jason P Fine; David M Mahvi
Journal:  Radiology       Date:  2004-12-15       Impact factor: 11.105

4.  Bulk ablation of soft tissue with intense ultrasound: modeling and experiments.

Authors:  T Douglas Mast; Inder Raj S Makin; Waseem Faidi; Megan M Runk; Peter G Barthe; Michael H Slayton
Journal:  J Acoust Soc Am       Date:  2005-10       Impact factor: 1.840

Review 5.  Treatment monitoring and thermometry for therapeutic focused ultrasound.

Authors:  I Rivens; A Shaw; J Civale; H Morris
Journal:  Int J Hyperthermia       Date:  2007-03       Impact factor: 3.914

Review 6.  Pathologic analysis of photothermal and photomechanical effects of laser-tissue interactions.

Authors:  S Thomsen
Journal:  Photochem Photobiol       Date:  1991-06       Impact factor: 3.421

Review 7.  The dielectric properties of biological tissues: I. Literature survey.

Authors:  C Gabriel; S Gabriel; E Corthout
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

8.  Thermal dose determination in cancer therapy.

Authors:  S A Sapareto; W C Dewey
Journal:  Int J Radiat Oncol Biol Phys       Date:  1984-06       Impact factor: 7.038

9.  In vivo thermal ablation monitoring using ultrasound echo decorrelation imaging.

Authors:  Swetha Subramanian; Steven M Rudich; Amel Alqadah; Chandra Priya Karunakaran; Marepalli B Rao; T Douglas Mast
Journal:  Ultrasound Med Biol       Date:  2013-11-14       Impact factor: 2.998

10.  An inverse problem approach to recovery of in vivo nanoparticle concentrations from thermal image monitoring of MR-guided laser induced thermal therapy.

Authors:  D Fuentes; A Elliott; J S Weinberg; A Shetty; J D Hazle; R J Stafford
Journal:  Ann Biomed Eng       Date:  2012-08-24       Impact factor: 3.934

View more
  1 in total

1.  Dependence of ultrasound echo decorrelation on local tissue temperature during ex vivo radiofrequency ablation.

Authors:  Swetha Subramanian; Daniel T Schmidt; Marepalli B Rao; T Douglas Mast
Journal:  Phys Med Biol       Date:  2016-03-04       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.