Literature DB >> 26349642

Versatility of tandem mass spectrometry for focused analysis of oxylipids.

Tania Petta1, Luiz A B Moraes2, Lúcia H Faccioli1.   

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the multiple reaction monitoring (MRM) scan mode has been the primary MS method applied for the target identification of specific and minor oxylipids in complex matrices, such as eicosanoids and docosanoids, which are potent lipid mediators derived from polyunsaturated fatty acid oxygenation. However, the high specificity of MRM can limit the detection of species with m/z MRM transitions not covered by the method. In addition to MRM, tandem-quadrupole mass analyzers enable other experiments to be conducted, by fragmenting ions via collision-induced dissociation process (CID). This paper presents the potential of tandem mass spectrometry for the focused analysis of oxylipids. We have successfully developed an LC-MS/MS method for the identification of precursor ions of m/z 115, a diagnostic product ion of 5-hydroxy- and 5-epoxy-fatty acids. As a proof of concept, the developed method was used to discover several oxylipids oxidized at C5 derived from arachidonic acid (C20 : 4) oxygenation in a hypothalamus rat extract that were not identified using the target MRM methodology. The proposed focused MS/MS-based approach in a tandem mass analyzer has proven to be a powerful strategy to accelerate the identification of oxylipids with structural similarities and assist the field of lipidomic research.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  eicosanoids; focused lipidomics; liquid chromatography-tandem mass spectrometry; multiple reaction monitoring; oxylipids; precursor ion scan

Mesh:

Substances:

Year:  2015        PMID: 26349642     DOI: 10.1002/jms.3595

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  3 in total

1.  Comprehensive high-resolution multiple-reaction monitoring mass spectrometry for targeted eicosanoid assays.

Authors:  Carlos Artério Sorgi; Ana Paula Ferranti Peti; Tania Petta; Alyne Fávero Galvão Meirelles; Caroline Fontanari; Luiz Alberto Beraldo de Moraes; Lúcia Helena Faccioli
Journal:  Sci Data       Date:  2018-08-21       Impact factor: 6.444

2.  The Quantitative Profiling of Oxylipins from Arachidonic Acid by LC-MS/MS in Feces at Birth 3 Days and 21 Days of Piglets.

Authors:  Ningning Huang; Xiangchen Liu; Xiaoqi Pei; Jian Peng; Hongkui Wei
Journal:  Metabolites       Date:  2022-07-28

Review 3.  Methods of the Analysis of Oxylipins in Biological Samples.

Authors:  Ivan Liakh; Alicja Pakiet; Tomasz Sledzinski; Adriana Mika
Journal:  Molecules       Date:  2020-01-15       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.