AIMS: We report the application of patient-specific computational models to plan the treatment of complex aortic re-coarctation (rCoA) with a proximal aberrant right subclavian artery in a patient who had previously undergone bare metal stenting. METHODS AND RESULTS: Clinically acquired images were used to set up patient-specific computational models for finite element (FE) and fluid dynamics (CFD) analyses. The 3D geometry was reconstructed from computed tomography and echocardiography images. Computer-generated deployment of a CP covered stent (NuMED, Hopkinton, NY, USA) at different diameters was tested using FE simulations. CFD analyses based on preoperative magnetic resonance flow measurements allowed assessment of rCoA pressure relief and right subclavian artery perfusion in the different scenarios. The simulations suggested an expansion diameter for the CP stent (8 zigs, length=28 mm) of between 16 and 18 mm to relieve the obstruction, cover the aneurysm and maintain satisfactory flow to the right subclavian artery. Following the modelling study, a 16 mm CP covered stent was successfully implanted. CONCLUSIONS: Patient-specific models can be successfully used to plan re-stenting of complex rCoA, showing the benefits of integrating computational techniques into patient management.
AIMS: We report the application of patient-specific computational models to plan the treatment of complex aortic re-coarctation (rCoA) with a proximal aberrant right subclavian artery in a patient who had previously undergone bare metal stenting. METHODS AND RESULTS: Clinically acquired images were used to set up patient-specific computational models for finite element (FE) and fluid dynamics (CFD) analyses. The 3D geometry was reconstructed from computed tomography and echocardiography images. Computer-generated deployment of a CP covered stent (NuMED, Hopkinton, NY, USA) at different diameters was tested using FE simulations. CFD analyses based on preoperative magnetic resonance flow measurements allowed assessment of rCoA pressure relief and right subclavian artery perfusion in the different scenarios. The simulations suggested an expansion diameter for the CP stent (8 zigs, length=28 mm) of between 16 and 18 mm to relieve the obstruction, cover the aneurysm and maintain satisfactory flow to the right subclavian artery. Following the modelling study, a 16 mm CP covered stent was successfully implanted. CONCLUSIONS: Patient-specific models can be successfully used to plan re-stenting of complex rCoA, showing the benefits of integrating computational techniques into patient management.
Authors: David C Wendell; Margaret M Samyn; Joseph R Cava; Mary M Krolikowski; John F LaDisa Journal: J Biomech Eng Date: 2016-09-01 Impact factor: 2.097
Authors: Giovanni Biglino; Claudio Capelli; Jan Bruse; Giorgia M Bosi; Andrew M Taylor; Silvia Schievano Journal: Heart Date: 2016-10-25 Impact factor: 5.994
Authors: Liam Swanson; Benjamin Owen; Amir Keshmiri; Amin Deyranlou; Thomas Aldersley; John Lawrenson; Paul Human; Rik De Decker; Barend Fourie; George Comitis; Mark E Engel; Bernard Keavney; Liesl Zühlke; Malebogo Ngoepe; Alistair Revell Journal: Front Bioeng Biotechnol Date: 2020-06-03
Authors: Giorgia M Bosi; Claudio Capelli; Mun Hong Cheang; Nicola Delahunty; Michael Mullen; Andrew M Taylor; Silvia Schievano Journal: J Biomech Date: 2018-02-20 Impact factor: 2.712