AIMS: We report the application of patient-specific computational models to plan the treatment of complex aortic re-coarctation (rCoA) with a proximal aberrant right subclavian artery in a patient who had previously undergone bare metal stenting. METHODS AND
RESULTS: Clinically acquired images were used to set up patient-specific computational models for finite element (FE) and fluid dynamics (CFD) analyses. The 3D geometry was reconstructed from computed tomography and echocardiography images. Computer-generated deployment of a CP covered stent (NuMED, Hopkinton, NY, USA) at different diameters was tested using FE simulations. CFD analyses based on preoperative magnetic resonance flow measurements allowed assessment of rCoA pressure relief and right subclavian artery perfusion in the different scenarios. The simulations suggested an expansion diameter for the CP stent (8 zigs, length=28 mm) of between 16 and 18 mm to relieve the obstruction, cover the aneurysm and maintain satisfactory flow to the right subclavian artery. Following the modelling study, a 16 mm CP covered stent was successfully implanted.
CONCLUSIONS: Patient-specific models can be successfully used to plan re-stenting of complex rCoA, showing the benefits of integrating computational techniques into patient management.

Entities:  

Mesh:

Year:  2015        PMID: 26348674     DOI: 10.4244/EIJY15M09_03

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  8 in total

1.  The Impact of Cardiac Motion on Aortic Valve Flow Used in Computational Simulations of the Thoracic Aorta.

Authors:  David C Wendell; Margaret M Samyn; Joseph R Cava; Mary M Krolikowski; John F LaDisa
Journal:  J Biomech Eng       Date:  2016-09-01       Impact factor: 2.097

Review 2.  Computational Fluid Dynamics and Additive Manufacturing to Diagnose and Treat Cardiovascular Disease.

Authors:  Amanda Randles; David H Frakes; Jane A Leopold
Journal:  Trends Biotechnol       Date:  2017-09-21       Impact factor: 19.536

3.  Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study.

Authors:  Francesco Sturla; Mattia Ronzoni; Mattia Vitali; Annalisa Dimasi; Riccardo Vismara; Georgia Preston-Maher; Gaetano Burriesci; Emiliano Votta; Alberto Redaelli
Journal:  J Biomech       Date:  2016-03-25       Impact factor: 2.712

Review 4.  Computational modelling for congenital heart disease: how far are we from clinical translation?

Authors:  Giovanni Biglino; Claudio Capelli; Jan Bruse; Giorgia M Bosi; Andrew M Taylor; Silvia Schievano
Journal:  Heart       Date:  2016-10-25       Impact factor: 5.994

5.  Patient-specific simulations for planning treatment in congenital heart disease.

Authors:  Claudio Capelli; Emilie Sauvage; Giuliano Giusti; Giorgia M Bosi; Hopewell Ntsinjana; Mario Carminati; Graham Derrick; Jan Marek; Sachin Khambadkone; Andrew M Taylor; Silvia Schievano
Journal:  Interface Focus       Date:  2017-12-15       Impact factor: 3.906

6.  A Patient-Specific CFD Pipeline Using Doppler Echocardiography for Application in Coarctation of the Aorta in a Limited Resource Clinical Context.

Authors:  Liam Swanson; Benjamin Owen; Amir Keshmiri; Amin Deyranlou; Thomas Aldersley; John Lawrenson; Paul Human; Rik De Decker; Barend Fourie; George Comitis; Mark E Engel; Bernard Keavney; Liesl Zühlke; Malebogo Ngoepe; Alistair Revell
Journal:  Front Bioeng Biotechnol       Date:  2020-06-03

7.  Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations.

Authors:  Giorgia M Bosi; Claudio Capelli; Mun Hong Cheang; Nicola Delahunty; Michael Mullen; Andrew M Taylor; Silvia Schievano
Journal:  J Biomech       Date:  2018-02-20       Impact factor: 2.712

8.  Evaluation of a modified Cheatham-Platinum stent for the treatment of aortic coarctation by finite element modelling.

Authors:  Barbara Eu Burkhardt; Nicholas Byrne; Marí Nieves Velasco Forte; Francesco Iannaccone; Matthieu De Beule; Gareth J Morgan; Tarique Hussain
Journal:  JRSM Cardiovasc Dis       Date:  2018-04-27
  8 in total