Abstract
The cold pressor test (CTP) as a diagnostic method of the circulatory system reactivity may be a basis for the qualification for thermal stimulation therapy. The aim of the work was a thermovisual assessment of the reaction to the Hines and Brown cold pressor test. A group of 30 healthy men in the age of 23.5 ± 0.8 years were examined. The average weight of the examinees was 78.4 ± 9.2 kg, their height 180.7 ± 5.9 cms, and BMI 23.9 ± 2.2 kg/m(2). A thermovisual picture of a tested and not tested hand of all the subjects was taken before and after the cold pressor test. Under the influence of cold water the surface temperature of a tested hand has decreased in a statistically significant way by 8.3°C on average, which is 29% of the temperature before the test, whilst the temperature of an untested hand dropped by 0.67°C. The decreases of temperature were not even and there was a statistically significant difference between the dorsal and palmar side of the hand. The correlation between the changes of systolic blood pressure and the hand surface temperature before and after CTP was observed.Entities:
Mesh:
Year: 2015 PMID: 26347884 PMCID: PMC4549536 DOI: 10.1155/2015/783642
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Blood pressure and heart rate before and after cold pressor test in the subjects.
|
| Mean ± SD | Rise |
| |
|---|---|---|---|---|
| SBP | Before | 124.0 ± 7.7 | 10.4 ± 4.9 |
|
| After | 134.4 ± 8.7 | |||
|
| ||||
| DBP | Before | 73.1 ± 6.4 | 7.9 ± 4.9 |
|
| After | 81.0 ± 7.1 | |||
|
| ||||
| HR | Before | 67.3 ± 8.2 | 5.4 ± 2.2 |
|
| After | 72.7 ± 8.3 | |||
SBP = systolic blood pressure.
DBP = diastolic blood pressure.
HR = heart rate [beats/min].
Average hand surface temperature before and after the cold pressor test.
|
| Mean ± SD | Difference ± SD |
| Difference ± SD |
| ||
|---|---|---|---|---|---|---|---|
| Right hand (tested) | Dorsal side | Before | 29.03 ± 1.33 | 9.00 ± 1.64 |
| 1.26 ± 0.88 |
|
| After | 20.03 ± 1.8 | ||||||
| Palmar side | Before | 28.75 ± 1.58 | 7.73 ± 1.62 |
| |||
| After | 21.01 ± 1.79 | ||||||
|
| |||||||
| Left hand (nontested) | Dorsal side | Before | 29.44 ± 1.31 | 0.78 ± 0.25 |
| 0.24 ± 0.32 |
|
| After | 28.64 ± 1.25 | ||||||
| Palmar side | Before | 28.79 ± 1.45 | 0.55 ± 0.23 |
| |||
| After | 28.24 ± 1.43 | ||||||
The correlation between the variations of blood pressure. Heart rate and surface temperature difference before and after the cold pressor test.
|
| Systolic blood pressure | Systolic blood pressure | Heart rate | |
|---|---|---|---|---|
| Right hand (tested) | Dorsal side | 0.530083 | 0.011761 | −0.147322 |
| Palmar side | 0.579772 | 0.180637 | −0.157786 | |
|
| ||||
| Left hand (nontested) | Dorsal side | −0.133289 | 0.320823 | −0.035817 |
| Palmar side | −0.051086 | 0.495889 | 0.217919 | |
Statistically significant p < 0.05.
The correlation between the heart rate and surface temperature difference before and after the cold pressor test.
| Heart rate | ||
|---|---|---|
| Right hand (tested) | Dorsal side | −0.147322 |
| Palmar side | −0.157786 | |
|
| ||
| Left hand (nontested) | Dorsal side | −0.035817 |
| Palmar side | 0.217919 | |
Statistically significant p < 0.05.
The correlation between the hand surface temperature differences before and after the cold pressor test.
| Temperature decrease | Relative temperature change in percentage | ||||||
|---|---|---|---|---|---|---|---|
|
| Right hand | Left hand | Right hand | Left hand | |||
| Palmar side | Dorsal side | Palmar side | Palmar side | Dorsal side | Palmar side | ||
| Right hand (tested) | Dorsal side | 0.83623 | 0.016915 | 0.91306 | |||
| Palmar side | −0.004946 | 0.010029 | |||||
|
| |||||||
| Left hand (nontested) | Dorsal side | 0.080591 | 0.004460 | 0.166778 | |||
Statistically significant p < 0.05.