Literature DB >> 26346033

Twenty-year outcome of aortic valve replacement with St. Jude Medical mechanical valves in Japanese patients.

Kenji Minakata1, Shiro Tanaka, Yohei Okawa, Tatsuo Kaneko, Shuichi Okonogi, Akihiko Usui, Tomonobu Abe, Nobushige Tamura, Shigeki Yanagi, Ryuzo Sakata.   

Abstract

BACKGROUND: Bioprostheses have become increasingly popular for aortic valve replacement (AVR) in recent years, but mechanical valves are still the standard choice, especially for younger patients. The aim of this study was to assess the very long-term outcomes in Japanese patients who underwent AVR with St. Jude Medical (SJM) mechanical valves. METHODS AND 
RESULTS: From 1991 to 2001, a total of 816 patients underwent AVR with SJM mechanical valves in 5 hospitals. Of these, 801 patients (mean age, 58.3±11.7 years) were analyzed in this study. There were 24 in-hospital deaths (3.0%). Mean follow-up duration was 11.6±6.7 years and the 10-year follow-up rate was 84.1%. Freedom from valve-related death at 5, 10, 15, and 20 years was 96.2%, 92.7%, 88.8%, and 86.6%, respectively. The linearized ratio of major bleeding events and thromboembolic events was 1.1% per patient-year and 1.0% per patient-year, respectively. Freedom from reoperation for the aortic prosthesis was 98.0% and 94.8% at 10 and 20 years, respectively.
CONCLUSIONS: The SJM mechanical valve provided excellent long-term freedom from valve-related death and reoperation in patients undergoing AVR. Therefore, this valve should be recommended to younger patients who wish to avoid reoperation.

Entities:  

Mesh:

Year:  2015        PMID: 26346033     DOI: 10.1253/circj.CJ-15-0793

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Spontaneous Prosthesis Leaflet Detachment and Loss During Aortic Valve Implantation.

Authors:  Emmanouel Papadakis; Thomas Martens; Meletios Kanakis
Journal:  J Cardiovasc Imaging       Date:  2022-04

2.  Ten-year experience of tricuspid valve replacement with the St. Jude medical valve.

Authors:  Xiliang Zhu; Yi Luo; Eryong Zhang; Qi An; Xijun Xiao; Li Dong; Yingqiang Guo; Ke Dian; Zhong Wu
Journal:  Sci Rep       Date:  2018-11-09       Impact factor: 4.379

  2 in total