Literature DB >> 26345126

Prototype AEGIS: A Pixel-Array Readout Circuit for Gamma-Ray Imaging.

H Bradford Barber1, F L Augustine2, L Furenlid1, C M Ingram1, G P Grim3.   

Abstract

Semiconductor detector arrays made of CdTe/CdZnTe are expected to be the main components of future high-performance, clinical nuclear medicine imaging systems. Such systems will require small pixel-pitch and much larger numbers of pixels than are available in current semiconductor-detector cameras. We describe the motivation for developing a new readout integrated circuit, AEGIS, for use in hybrid semiconductor detector arrays, that may help spur the development of future cameras. A basic design for AEGIS is presented together with results of an HSPICE™ simulation of the performance of its unit cell. AEGIS will have a shaper-amplifier unit cell and neighbor pixel readout. Other features include the use of a single input power line with other biases generated on-board, a control register that allows digital control of all thresholds and chip configurations and an output approach that is compatible with list-mode data acquisition. An 8×8 prototype version of AEGIS is currently under development; the full AEGIS will be a 64×64 array with 300 μm pitch.

Entities:  

Keywords:  CZT; CdTe; CdZnTe; hybrid detector; medical imaging; nuclear medicine; readout integrated circuit; semiconductor camera; semiconductor detector

Year:  2005        PMID: 26345126      PMCID: PMC4558928          DOI: 10.1117/12.624924

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  4 in total

1.  Charge transport in arrays of semiconductor gamma-ray detectors.

Authors: 
Journal:  Phys Rev Lett       Date:  1995-07-03       Impact factor: 9.161

2.  SemiSPECT: A Small-animal Imaging System Based on Eight CdZnTe Pixel Detectors.

Authors:  Todd E Peterson; Hyunki Kim; Michael J Crawford; Benjamin M Gershman; William C J Hunter; H Bradford Barber; Lars R Furenlid; Donald W Wilson; James M Woolfenden; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2002-11-10

3.  Evaluation of a small cadmium zinc telluride detector for scintimammography.

Authors:  Bryon Mueller; Michael K O'Connor; Ira Blevis; Deborah J Rhodes; Robin Smith; Douglas A Collins; Stephen W Phillips
Journal:  J Nucl Med       Date:  2003-04       Impact factor: 10.057

4.  Spatial Pileup Considerations for Pixellated Gamma -ray Detectors.

Authors:  L R Furenlid; E Clarkson; D G Marks; H H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2002-08-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.