Literature DB >> 26344088

Feasibility of markerless tumor tracking by sequential dual-energy fluoroscopy on a clinical tumor tracking system.

Jennifer Dhont1, Dirk Verellen2, Kenneth Poels2, Koen Tournel2, Manuela Burghelea2, Thierry Gevaert2, Christine Collen2, Benedikt Engels2, Robbe Van Den Begin2, Nico Buls3, Gert Van Gompel3, Toon Van Cauteren3, Guy Storme2, Mark De Ridder2.   

Abstract

A novel approach to dual-energy imaging for markerless tumor tracking was proposed consisting of sequential dual-energy fluoroscopy, omitting the need for fast-switching kV generators. The implementation of this approach on a clinical tumor tracking system and its efficacy is shown feasible through optimization of the imaging parameters.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Dual-energy; Fluoroscopy; Markerless; Tracking

Mesh:

Substances:

Year:  2015        PMID: 26344088     DOI: 10.1016/j.radonc.2015.08.021

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Evaluation of a template-based algorithm for markerless lung tumour localization on single- and dual-energy kilovoltage images.

Authors:  Alec M Block; Rakesh Patel; Murat Surucu; Matthew M Harkenrider; John C Roeske
Journal:  Br J Radiol       Date:  2016-10-12       Impact factor: 3.039

2.  A Bayesian approach for three-dimensional markerless tumor tracking using kV imaging during lung radiotherapy.

Authors:  Chun-Chien Shieh; Vincent Caillet; Michelle Dunbar; Paul J Keall; Jeremy T Booth; Nicholas Hardcastle; Carol Haddad; Thomas Eade; Ilana Feain
Journal:  Phys Med Biol       Date:  2017-03-21       Impact factor: 3.609

3.  The markerless lung target tracking AAPM Grand Challenge (MATCH) results.

Authors:  Marco Mueller; Per Poulsen; Rune Hansen; Wilko Verbakel; Ross Berbeco; Dianne Ferguson; Shinichiro Mori; Lei Ren; John C Roeske; Lei Wang; Pengpeng Zhang; Paul Keall
Journal:  Med Phys       Date:  2021-12-29       Impact factor: 4.071

4.  Characterization of Markerless Tumor Tracking Using the On-Board Imager of a Commercial Linear Accelerator Equipped With Fast-kV Switching Dual-Energy Imaging.

Authors:  John C Roeske; Hassan Mostafavi; Maksat Haytmyradov; Adam Wang; Daniel Morf; Luca Cortesi; Murat Surucu; Rakesh Patel; Roberto Cassetta; Liangjia Zhu; Mathias Lehmann; Matthew M Harkenrider
Journal:  Adv Radiat Oncol       Date:  2020-03-02

5.  Markerless tumor tracking using fast-kV switching dual-energy fluoroscopy on a benchtop system.

Authors:  Maksat Haytmyradov; Hassan Mostafavi; Adam Wang; Liangjia Zhu; Murat Surucu; Rakesh Patel; Arun Ganguly; Michelle Richmond; Roberto Cassetta; Matthew M Harkenrider; John C Roeske
Journal:  Med Phys       Date:  2019-06-01       Impact factor: 4.071

6.  Adaptive weighted log subtraction based on neural networks for markerless tumor tracking using dual-energy fluoroscopy.

Authors:  Maksat Haytmyradov; Hassan Mostafavi; Roberto Cassetta; Rakesh Patel; Murat Surucu; Liangjia Zhu; John C Roeske
Journal:  Med Phys       Date:  2020-01-10       Impact factor: 4.071

7.  Real-time markerless tumour tracking with patient-specific deep learning using a personalised data generation strategy: proof of concept by phantom study.

Authors:  Wataru Takahashi; Shota Oshikawa; Shinichiro Mori
Journal:  Br J Radiol       Date:  2020-02-28       Impact factor: 3.039

8.  Novel real-time tumor-contouring method using deep learning to prevent mistracking in X-ray fluoroscopy.

Authors:  Toshiyuki Terunuma; Aoi Tokui; Takeji Sakae
Journal:  Radiol Phys Technol       Date:  2017-12-28

Review 9.  Technical Principles of Dual-Energy Cone Beam Computed Tomography and Clinical Applications for Radiation Therapy.

Authors:  Shailaja Sajja; Young Lee; Markus Eriksson; Håkan Nordström; Arjun Sahgal; Masoud Hashemi; James G Mainprize; Mark Ruschin
Journal:  Adv Radiat Oncol       Date:  2019-07-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.