Literature DB >> 26343822

Reliability of 2 Different Positioning Protocols for Dual-Energy X-ray Absorptiometry Measurement of Body Composition in Healthy Adults.

Ava Kerr1, Gary J Slater2, Nuala Byrne3, Alisa Nana4.   

Abstract

Dual-energy X-ray absorptiometry (DXA) is an accepted time-efficient method of body composition assessment for total body and regional fat mass (FM), lean mass (LM), and bone mineral content (BMC), but for longitudinal monitoring the measurements must be sufficiently reliable. The aim of this study was to compare the reliability of a new positioning protocol (Nana et al) with the current reference (National Health and Nutrition Examination Survey [NHANES]) protocol and investigate their within-protocol precision. Thirty healthy adults (16 females and 14 males) underwent 4 whole-body DXA scans in succession with full repositioning between scans. The scan order was randomized, with 2 scans undertaken in accordance with the current NHANES protocol and 2 using the Nana et al protocol. Magnitudes of typical errors of measurement and changes in the mean of DXA body composition estimates were assessed as standardized effect sizes. The Nana et al protocol repositioning produced trivial typical errors for total body across all LM estimates except for FM in the arms and trunk which were moderately substantial. The NHANES protocol produced similar typical errors for all measurements in LM except for FM and BMC in the trunk and arms which were substantially larger than the smallest worthwhile effect. The difference between protocols produced substantially large typical errors in estimations of both total body FM and regional FM and BMC, but differences in LM were all less than the smallest worthwhile effect. Although both protocols demonstrated acceptable intratest reliability, the Nana et al protocol produced enhanced precision in regional (arms and trunk) FM and BMC. The protocols were substantially different in body composition assessment especially for FM and thus should not to be interchanged. Anecdotally, subjects felt more comfortable and supported during the scan with the Nana et al protocol.
Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

Keywords:  Body composition; dual-energy X-ray absorptiometry; reliability

Mesh:

Year:  2015        PMID: 26343822     DOI: 10.1016/j.jocd.2015.08.002

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  7 in total

1.  Evaluating Muscle Mass in Survivors of Acute Respiratory Distress Syndrome: A 1-Year Multicenter Longitudinal Study.

Authors:  Kitty S Chan; Marina Mourtzakis; Lisa Aronson Friedman; Victor D Dinglas; Catherine L Hough; E Wesley Ely; Peter E Morris; Ramona O Hopkins; Dale M Needham
Journal:  Crit Care Med       Date:  2018-08       Impact factor: 7.598

2.  A randomised controlled intervention study investigating the efficacy of carotenoid-rich fruits and vegetables and extra-virgin olive oil on attenuating sarcopenic symptomology in overweight and obese older adults during energy intake restriction: protocol paper.

Authors:  Anthony Villani; Hattie Wright; Gary Slater; Jonathan Buckley
Journal:  BMC Geriatr       Date:  2018-01-05       Impact factor: 3.921

3.  Investigating the level of agreement of two positioning protocols when using dual energy X-ray absorptiometry in the assessment of body composition.

Authors:  Flinn Shiel; Carl Persson; Vini Simas; James Furness; Mike Climstein; Ben Schram
Journal:  PeerJ       Date:  2017-10-16       Impact factor: 2.984

4.  Estimates of the precision of regional and whole body composition by dual-energy x-ray absorptiometry in persons with chronic spinal cord injury.

Authors:  Ashraf S Gorgey; Christopher M Cirnigliaro; William A Bauman; Robert A Adler
Journal:  Spinal Cord       Date:  2018-03-06       Impact factor: 2.772

5.  Overuse injuries in Swedish elite athletics- a study protocol for a prospective multifactorial cohort study.

Authors:  Andreas Lundberg Zachrisson; Pia Desai; Jon Karlsson; Elias Johanesson; Stefan Grau
Journal:  BMC Musculoskelet Disord       Date:  2018-10-13       Impact factor: 2.362

6.  Body weight and subcutaneous fat patterning in elite judokas.

Authors:  Marietta Sengeis; Wolfram Müller; Paul Störchle; Alfred Führhapter-Rieger
Journal:  Scand J Med Sci Sports       Date:  2019-07-17       Impact factor: 4.221

7.  Weight Loss after 12 Weeks of Exercise and/or Nutritional Guidance Is Not Obligatory for Induced Changes in Local Fat/Lean Mass Indexes in Adults with Excess of Adiposity.

Authors:  Robinson Ramírez-Vélez; Mikel Izquierdo; Karem Castro-Astudillo; Carolina Medrano-Mena; Angela Liliana Monroy-Díaz; Rocío Del Pilar Castellanos-Vega; Héctor Reynaldo Triana-Reina; María Correa-Rodríguez
Journal:  Nutrients       Date:  2020-07-26       Impact factor: 5.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.