Literature DB >> 26343438

Triple quadrupole tandem mass spectrometry: A real alternative to high resolution magnetic sector instrument for the analysis of polychlorinated dibenzo-p-dioxins, furans and dioxin-like polychlorinated biphenyls.

Ángel García-Bermejo1, Manuela Ábalos2, Jordi Sauló2, Esteban Abad2, María José González1, Belén Gómara3.   

Abstract

This paper reports on the optimisation, characterisation, validation and applicability of gas chromatography coupled to triple quadrupole mass spectrometry in its tandem operation mode (GC-QqQ(MS/MS) for the quantification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs, dioxins) and dioxin-like polychlorinated biphenyls (DL-PCBs) in environmental and food matrices. MS/MS parameters were selected to achieve the high sensitivity and selectivity required for the analysis of this type of compounds and samples. Good repeatability for areas (RSD = 1-10%, for PCDD/Fs and DL-PCBs) and for ion transition ratios (RSD = 0.3-10%, for PCDD/Fs, and 0.2-15%, for DL-PCBs) and low instrumental limits of detection, 0.07-0.75 pg μL(-1) (for dioxins) and 0.05-0.63 pg μL(-1) (for DL-PCBs), were obtained. A comparative study of the congener specific determination using both GC-QqQ(MS/MS) and gas chromatography-high resolution mass spectrometry (GC-HRMS) was also performed by analysing several fortified samples and certified reference materials (CRMs) with low (feed and foodstuffs), median (sewage sludge) and high (fly ash) toxic equivalency (TEQ) concentration levels, i.e. 0.60, 1.83, 72.9 and 3609 pg WHO-TEQ(PCDD/Fs) g(-1). The agreement between the results obtained for the total TEQs (dioxins) on GC-QqQ(MS/MS) and GC-HRMS in all the investigated samples were within the range of ±4%, and that of DL-PCBs at concentration levels of 0.84 pg WHO-TEQs (DL-PCBs) g(-1), in the case of feedstuffs, was 0.11%. Both instrumental methods have similar and comparable linearity, precision and accuracy. The GC-QqQ(MS/MS) sensitivity, lower than that of GC-HRMS, is good enough (iLODs in the down to low pg levels) to detect the normal concentrations of these compounds in food and environmental samples. These results make GC-QqQ(MS/MS) suitable for the quantitative analysis of dioxins and DL-PCBs and a real alternative tool to the reference sector HRMS instruments.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dioxin-like polychlorinated biphenyls; Environmental samples; Foodstuffs; Gas chromatography; Polychlorinated dibenzo-p-dioxins; Triple quadrupole mass spectrometry

Mesh:

Substances:

Year:  2015        PMID: 26343438     DOI: 10.1016/j.aca.2015.07.039

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  QUICK: Quality and Usability Investigation and Control Kit for Mass Spectrometric Data from Detection of Persistent Organic Pollutants.

Authors:  Wenjing Guo; Jeffrey Archer; Morgan Moore; Jeffrey Bruce; Michelle McLain; Sina Shojaee; Wen Zou; Linda A Benjamin; Anthony Adeuya; Russell Fairchild; Huixiao Hong
Journal:  Int J Environ Res Public Health       Date:  2019-10-30       Impact factor: 3.390

Review 2.  Persistent Organic Pollutants in Food: Contamination Sources, Health Effects and Detection Methods.

Authors:  Wenjing Guo; Bohu Pan; Sugunadevi Sakkiah; Gokhan Yavas; Weigong Ge; Wen Zou; Weida Tong; Huixiao Hong
Journal:  Int J Environ Res Public Health       Date:  2019-11-08       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.