Literature DB >> 26342630

Effects of ventilation modalities on near-infrared spectroscopy in surgically corrected CDH infants.

Andrea Conforti1, Paola Giliberti2, Francesca Landolfo2, Laura Valfrè2, Claudia Columbo2, Vito Mondi2, Irma Capolupo2, Andrea Dotta2, Pietro Bagolan2.   

Abstract

BACKGROUND: Near-infrared spectroscopy (NIRS) is a noninvasive technique for monitoring tissue oxygenation and perfusion. The aim of this study was to evaluate cerebral and splanchnic NIRS changes in CDH operated infants enrolled into the VICI trial and therefore randomized for ventilatory modalities.
MATERIALS AND METHODS: CDH newborns enrolled into the VICI trial (Netherlands Trial Register, NTR 1310) were randomized at birth for high-frequency oscillatory ventilation (HFOV) or conventional mechanical ventilation (CMV) according to the trial. Cerebral oxygenation (rSO2C) and splanchnic oxygenation (rSO2S) were obtained by NIRS (INVOS 5100; Somanetics, Troy, MI) before and after surgery. Variations in rSO2C and rSO2S were evaluated. Mann-Whitney test and one-way ANOVA were used as appropriate. p<0.05 was considered significant.
RESULTS: Thirteen VICI trial patients underwent surgical repair between March 2011 and December 2012, and were enrolled in the study. Seven patients were assigned to HFOV and six to CMV group respectively. During surgery, a significant reduction in rSO2C (p=0.0001) and rSO2S (p=0.005) were observed. HFOV patients experienced prolonged reduction in rSO2C value (p=0.003) while rSO2S did not vary between HFOV and CMV (p=0.94).
CONCLUSIONS: Surgical CDH repair was associated with decrease of cerebral and splanchnic oxygenation, regardless of ventilation. Patients ventilated by HFOV need a longer time interval to recovery normal rSO2C values, than those ventilated by CMV. This may be owing to a different impact of HFOV on patients' hemodynamic status with a higher impairment on total venous return and its negative consequences on cardiac output.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  CMV; Congenital diaphragmatic hernia; HFOV; NIRS; conventional mechanical ventilation; high-frequency oscillatory ventilation

Mesh:

Year:  2015        PMID: 26342630     DOI: 10.1016/j.jpedsurg.2015.07.021

Source DB:  PubMed          Journal:  J Pediatr Surg        ISSN: 0022-3468            Impact factor:   2.545


  7 in total

Review 1.  [Near-infrared spectroscopy : Technique, development, current use and perspectives].

Authors:  D Bolkenius; C Dumps; B Rupprecht
Journal:  Anaesthesist       Date:  2021-03       Impact factor: 1.041

2.  Early detection of necrotizing enterocolitis using broadband optical spectroscopy.

Authors:  Seth D Goldstein; Robert J Beaulieu; Diego F Niño; Young Chun; Amit Banerjee; Chhinder P Sodhi; David J Hackam
Journal:  J Pediatr Surg       Date:  2018-03-07       Impact factor: 2.545

3.  Monitoring Cerebral and Renal Oxygenation Status during Neonatal Digestive Surgeries Using Near Infrared Spectroscopy.

Authors:  Jonathan Beck; Gauthier Loron; Claire Masson; Marie-Laurence Poli-Merol; Eliane Guyot; Camille Guillot; Nathalie Bednarek; Caroline François
Journal:  Front Pediatr       Date:  2017-06-14       Impact factor: 3.418

Review 4.  Monitoring Cerebral Oxygenation in Neonates: An Update.

Authors:  Laura Marie Louise Dix; Frank van Bel; Petra Maria Anna Lemmers
Journal:  Front Pediatr       Date:  2017-03-14       Impact factor: 3.418

Review 5.  Renal Tissue Oxygenation Monitoring-An Opportunity to Improve Kidney Outcomes in the Vulnerable Neonatal Population.

Authors:  Matthew W Harer; Valerie Y Chock
Journal:  Front Pediatr       Date:  2020-05-14       Impact factor: 3.418

Review 6.  Respiratory Support of Infants With Congenital Diaphragmatic Hernia.

Authors:  Emma Williams; Anne Greenough
Journal:  Front Pediatr       Date:  2021-12-24       Impact factor: 3.418

7.  Comparison of basic regional cerebral oxygen saturation values in patients of different ages: a pilot study.

Authors:  Chaohui Lian; Peng Li; Ning Wang; Yi Lu; Wangning Shangguan
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.