Literature DB >> 26342555

Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures.

Thomas K Schaefer1, Christian Spross1, Karl K Stoffel2, Piers J Yates3.   

Abstract

OBJECTIVES: Displaced intracapsular neck of femur fractures (NOF) in younger patients are usually fixed with partially-threaded cannulated screws. However posterior comminution may lead to construct failure. We hypothesised that a posterior fully threaded positioning screw would enhance stability.
METHODS: A total of 16 left composite femora (Sawbone) were used for testing. To mimic a subcapital fracture with posterior comminution, a subcaptial osteotomy was performed and a posterior wedge was resected from the neck. Group A (n=8) was fixed using 3 partially threaded cancellous screws. In Group B (n=8), a fully threaded positioning screw instead of a partially threaded was used posteriorly. The specimens were tested for bending (antero-posterior=A-P) and axial stiffness. Finally, they were axially loaded up to failure or up to 10,000 cycles and the final displacement was measured at the site of the resected neck. More than 5mm of displacement was considered as a failure of the construct.
RESULTS: Group B showed significantly higher average A-P stiffness (665±17N/mm compared to 414±41N/mm, p=0.0004); whereas axial stiffness did not significantly differ between the two groups (p=0.301). In Group B, the mean final displacement after cyclic axial loading was 0.51±0.13mm and none of the specimens failed, whereas 7 of 8 constructs failed in Group A (p=0.001).
CONCLUSIONS: This biomechanical study points out a potential benefit of replacing the posterior partially threaded cancellous screw with a fully threaded positioning screw in subcapital NOF with posterior comminution. The construct with the fully threaded screw significantly improved the A-P stiffness and reduced the collapse of the fracture.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cannulated screws; Fully threaded screw; NOF; Neck of femur fracture; Partially threaded screw

Mesh:

Year:  2015        PMID: 26342555     DOI: 10.1016/j.injury.2015.07.021

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  7 in total

1.  Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex.

Authors:  Jingwen Liu; Baokun Zhang; Bohao Yin; Hongchi Chen; Hui Sun; Wei Zhang
Journal:  Biomed Res Int       Date:  2019-07-07       Impact factor: 3.411

2.  Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis.

Authors:  Shi Zhan; Dajun Jiang; Jian Xu; Ming Ling; Kai Yang; Yuehua Li; Weitao Jia; Hai Hu; Changqing Zhang
Journal:  BMC Musculoskelet Disord       Date:  2020-12-12       Impact factor: 2.362

3.  An original method of simulating the articular cartilage in the context of in vitro biomechanical studies investigating the proximal femur.

Authors:  Teodor Stefan Gheorghevici; Eugen Carata; Paul-Dan Sirbu; Ovidiu Alexa; Manuela-Gabi Poroh; Alexandru Filip; Norin Forna; Bogdan Puha
Journal:  Exp Ther Med       Date:  2022-01-05       Impact factor: 2.447

4.  Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults.

Authors:  Kai-Xuan Yuan; Fan Yang; You-Shui Gao; Peng-Bo Luo; Kai Fu; Dao-Yu Zhu; Chen-Yi Jiang; Dong-Xu Jin; Ze-Hao Wang; Xiao-Yuan Peng
Journal:  J Orthop Surg Res       Date:  2022-02-20       Impact factor: 2.359

5.  Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures.

Authors:  Jiantao Li; Menglin Wang; Lianting Li; Hao Zhang; Ming Hao; Chen Li; Lin Han; Jianfeng Zhou; Kun Wang
Journal:  J Orthop Surg Res       Date:  2018-10-29       Impact factor: 2.359

6.  The effect of bone morphogenetic protein 2 composite materials combined with cannulated screws in treatment of acute displaced femoral neck fractures.

Authors:  Hongwei Gao; Deguo Xing; Zhonghao Liu; Jiachun Zheng; Zhenggang Xiong; Mingzhi Gong; Lan Liu
Journal:  Medicine (Baltimore)       Date:  2020-02       Impact factor: 1.817

7.  Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study.

Authors:  Yilin Wang; Na Han; Dianying Zhang; Peixun Zhang; Baoguo Jiang
Journal:  Sci Rep       Date:  2022-02-02       Impact factor: 4.379