Hydrophilic interaction chromatography coupled to tandem mass spectrometry in the presence of hydrophilic ion-pairing reagents for the separation of nucleosides and nucleotide mono-, di- and triphosphates.

María Mateos-Vivas1, Encarnación Rodríguez-Gonzalo2, Diego García-Gómez1, Rita Carabias-Martínez1.   

Abstract

A fast and efficient method for the simultaneous separation of highly polar compounds, in this case nucleosides and nucleotide mono-, di- and triphosphates, using hydrophilic interaction chromatography coupled with tandem mass spectrometry (HILIC-MS/MS) is proposed. This new separation method revealed the possibilities of the formation of hydrophilic ion-pairing compounds. Three stationary phases (HILIC XBridge-Amide, HILIC-CoreShell and ZIC-HILIC) were assayed for the separation of 20 target analytes, and a detailed study of the composition of the mobile phase was made using different salts at different concentrations in a organic-rich mobile phase. We report that in order to prevent the adsorption of nucleotides on the LC-MS setup and to enhance their retention on the HILIC stationary phase, a mobile phase containing hexafluoro-2-propanol and different cations should be used. Four cations were evaluated: ammonium, diethylammonium, triethylammonium and tetrabutylammonium. The results revealed the formation of an ionic-association compound between the phosphorylated analytes and the cationic ion-pairing reagents, whose retention increased with the polarity of the cationic ion-pairing reagent. HILIC XBridge-Amide was found to be the most suitable column for the separation of these analytes, and the optimized mobile phase consisted of an ACN/UHQ water mixture (3min of isocratic elution using 82:18%, v/v and then a fast gradient from 18% to 22% of water) with 100mM hexafluoro-2-propanol and 50mM diethylamine (w(w)pH 9-w(s)pH 10). In a total analysis time of 8min, good results were achieved in terms of resolution. Under these optimum conditions, a further comprehensive study of the retention mechanism was carried out.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hydrophilic interaction chromatography (HILIC); Hydrophilic ion-pairing; Nucleosides; Nucleotide mono-, di- and triphosphates

Mesh:

Substances:

Year:  2015        PMID: 26341591     DOI: 10.1016/j.chroma.2015.08.040

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Oligonucleotide analysis by hydrophilic interaction liquid chromatography-mass spectrometry in the absence of ion-pair reagents.

Authors:  Peter A Lobue; Manasses Jora; Balasubrahmanyam Addepalli; Patrick A Limbach
Journal:  J Chromatogr A       Date:  2019-02-07       Impact factor: 4.759

2.  Challenges and stepwise fit-for-purpose optimization for bioanalyses of remdesivir metabolites nucleotide monophosphate and triphosphate in mouse tissues using LC-MS/MS.

Authors:  Wenjuan Hu; Lu Chang; Changqiang Ke; Yuanchao Xie; Jingshan Shen; Bo Tan; Jia Liu
Journal:  J Pharm Biomed Anal       Date:  2020-11-30       Impact factor: 3.935

3.  Hydrophilic Interaction Liquid Chromatography Coupled to Mass Spectrometry and Multivariate Analysis of the De Novo Pyrimidine Pathway Metabolites.

Authors:  Paula Galeano Garcia; Barbara H Zimmermann; Chiara Carazzone
Journal:  Biomolecules       Date:  2019-07-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.