Literature DB >> 26341249

Jarvik 2000 axial-flow ventricular assist device placement to a systemic morphologic right ventricle in congenitally corrected transposition of the great arteries.

Yoshihisa Tanoue1, Yuki Jinzai2, Ryuji Tominaga2.   

Abstract

Few descriptions of the implantation and management of an implantable ventricular assist device in patients with complex congenital heart disease exist in the literature. The Jarvik 2000 axial-flow ventricular assist device (Jarvik Heart, Inc., NYC, NY, USA) can be placed in either the left or the right ventricle. We present the case of a 60-year-old man with congenitally corrected transposition of the great arteries who underwent successful placement of a Jarvik 2000 axial-flow ventricular assist device in a systemic morphologic right ventricle.

Entities:  

Keywords:  Congenitally corrected transposition of the great arteries; Jarvik 2000; Ventricular assist device

Mesh:

Year:  2015        PMID: 26341249     DOI: 10.1007/s10047-015-0866-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  8 in total

1.  Mechanical circulatory support of systemic ventricle in adults with transposition of great arteries.

Authors:  Michael Huebler; Alexander Stepanenko; Thomas Krabatsch; Evgenij V Potapov; Roland Hetzer
Journal:  ASAIO J       Date:  2012 Jan-Feb       Impact factor: 2.872

Review 2.  Jarvik 2000 pump technology and miniaturization.

Authors:  Robert Jarvik
Journal:  Heart Fail Clin       Date:  2013-10-10       Impact factor: 3.179

3.  Clinical report of long-term support with dual Jarvik 2000 biventricular assist device.

Authors:  Shunsuke Saito; Taichi Sakaguchi; Yoshiki Sawa
Journal:  J Heart Lung Transplant       Date:  2011-04-03       Impact factor: 10.247

4.  Mechanical circulatory support in patients with heart failure secondary to transposition of the great arteries.

Authors:  David L Joyce; Sheri S Crow; Ranjit John; James D St Louis; Elizabeth A Braunlin; Lee A Pyles; Paula Kofflin; Lyle D Joyce
Journal:  J Heart Lung Transplant       Date:  2010-11       Impact factor: 10.247

5.  HeartWare ventricular assist device placement in a patient with congenitally corrected transposition of the great arteries.

Authors:  Jiapeng Huang; Mark S Slaughter
Journal:  J Thorac Cardiovasc Surg       Date:  2012-12-06       Impact factor: 5.209

Review 6.  Valvular heart disease in patients supported with left ventricular assist devices.

Authors:  Teresa S Wang; Adrian F Hernandez; G Michael Felker; Carmelo A Milano; Joseph G Rogers; Chetan B Patel
Journal:  Circ Heart Fail       Date:  2014-01       Impact factor: 8.790

7.  Successful ventricular assist device placement in transposition of the great arteries with pulmonary hypertension.

Authors:  Navin Rajagopalan; David C Booth; Enrique Diaz-Guzman; Charles W Hoopes
Journal:  Ann Thorac Surg       Date:  2013-02       Impact factor: 4.330

8.  Ventricular assist device outflow graft in congenitally corrected transposition of great arteries - a surgical challenge.

Authors:  Prashant N Mohite; Aron F Popov; Diana Garcia; Rachel Hards; Bartlomeij Zych; Asghar Khaghani; Andre R Simon
Journal:  J Cardiothorac Surg       Date:  2012-09-26       Impact factor: 1.637

  8 in total
  5 in total

Review 1.  Journal of Artificial Organs 2016: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2017-02-14       Impact factor: 1.731

Review 2.  Durable mechanical circulatory support in teenagers and adults with congenital heart disease: A systematic review.

Authors:  Jill M Steiner; Eric V Krieger; Karen K Stout; April Stempien-Otero; Claudius Mahr; Nahush A Mokadam; Joshua L Hermsen
Journal:  Int J Cardiol       Date:  2017-08-02       Impact factor: 4.164

Review 3.  Heart transplantation for adults with congenital heart disease: current status and future prospects.

Authors:  Hikaru Matsuda; Hajime Ichikawa; Takayoshi Ueno; Yoshiki Sawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-04-24

4.  Effects of Cone-Shaped Bend Inlet Cannulas of an Axial Blood Pump on Thrombus Formation: An Experiment and Simulation Study.

Authors:  Guangmao Liu; Jianye Zhou; Hansong Sun; Yan Zhang; Haibo Chen; Shengshou Hu
Journal:  Med Sci Monit       Date:  2017-04-05

5.  2019 EACTS Expert Consensus on long-term mechanical circulatory support.

Authors:  Evgenij V Potapov; Christiaan Antonides; Maria G Crespo-Leiro; Alain Combes; Gloria Färber; Margaret M Hannan; Marian Kukucka; Nicolaas de Jonge; Antonio Loforte; Lars H Lund; Paul Mohacsi; Michiel Morshuis; Ivan Netuka; Mustafa Özbaran; Federico Pappalardo; Anna Mara Scandroglio; Martin Schweiger; Steven Tsui; Daniel Zimpfer; Finn Gustafsson
Journal:  Eur J Cardiothorac Surg       Date:  2019-08-01       Impact factor: 4.191

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.