Is it a typical crosstalk: Need for re-implantation?

Zeynettin Kaya1, Kursat Akbuga2, Alpay Aribas2, Ilknur Can2.   

Abstract

With constantly evolving technology and an ever-increasing number of patients with pacemakers, clinicians will encounter various pacemaker malfunctions in their practice. While some of these issues can be solved even by using only the pacemaker׳s mode settings, others require re-intervention; neglecting a pacemaker׳s malfunction without full investigation threatens the patient׳s life. In this report, we describe a patient with a dual-chamber pacemaker with neglected or unresolved dyssynchronization that occurred 2 years after implantation.

Entities:  

Keywords:  Crosstalk; Dislocation; Lead switch; Pacemaker; Safety mode

Year:  2014        PMID: 26335694      PMCID: PMC4550195          DOI: 10.1016/j.joa.2014.07.004

Source DB:  PubMed          Journal:  J Arrhythm        ISSN: 1880-4276


  5 in total

1.  An intracardiac pacemaker for Stokes-Adams seizures.

Authors:  S FURMAN; J B SCHWEDEL
Journal:  N Engl J Med       Date:  1959-11-05       Impact factor: 91.245

Review 2.  Pacing features that mimic malfunction: a review of current programmable and automated device functions that cause confusion in the clinical setting.

Authors:  Michael S Lloyd; Mikhael F El Chami; Jonathan J Langberg
Journal:  J Cardiovasc Electrophysiol       Date:  2009-04

3.  Pacemaker interrogation showing virtually no ventricular pacing in a ventricular pacing dependent patient: what is the explanation?

Authors:  Gholamreza Davoodi; Negar Faramarzi; Akbar Shafiee; Ali Kazemisaeed
Journal:  Anadolu Kardiyol Derg       Date:  2013-09-10

4.  Pacemaker malfunction due to atrial and ventricular leads switched in the header: two faces of the same mistake?

Authors:  Marek Jastrzebski
Journal:  Pacing Clin Electrophysiol       Date:  2008-06       Impact factor: 1.976

5.  Atrial and ventricular lead switch at the pacemaker header: why did asystole first occur 3 years later?

Authors:  Amar Al Hamdi; Marek Jastrzębski; Jawad M Hawas
Journal:  Pacing Clin Electrophysiol       Date:  2013-04-22       Impact factor: 1.976

  5 in total
  3 in total

1.  Syncope in a patient with a dual-chamber pacemaker: What is the possible mechanism?

Authors:  Yavuzer Koza; Ziya Simsek; Selim Aydemir; Remziye Doğan
Journal:  J Arrhythm       Date:  2016-10-07

2.  Kaya et al. Is it a typical crosstalk: Need for re-implantation?

Authors:  Mohammad Ali Akbarzadeh
Journal:  J Arrhythm       Date:  2015-06-16

Review 3.  A review on algae and plants as potential source of arachidonic acid.

Authors:  Sanaa M M Shanab; Rehab M Hafez; Ahmed S Fouad
Journal:  J Adv Res       Date:  2018-03-13       Impact factor: 10.479

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.