Measuring the Repeatability of Simulated Physiology in Simulators.

David Cumin1, Charlotte Chen, Alan F Merry.   

Abstract

BACKGROUND: In simulation, it may be important in some instances that the physiologic responses to given interventions are substantially repeatable. However, there is no agreed approach to evaluating the repeatability of simulators. We therefore aimed to develop such an approach.
METHODS: In repeated simulations, we evaluated the physiologic responses to 7 simple clinical interventions generated by a METI (Medical Education Technologies Incorporated, Sarasota, FL) HPS (Human Patient Simulator) simulator in connected and disconnected states and the screen-based Anesoft Anesthesia Simulator. For a selection of variables, we calculated 3 objective measures of similarity (root mean squared error, median performance error, and median absolute performance error). We also calculated divergence over time and compared 3 preprocessing techniques to reduce the effect of clinically irrelevant phase and frequency differences (simple phase shift, complex phase shift, and dynamic time warping).
RESULTS: We collected data from more than 85 hours of simulation time from 255 simulations. The Anesoft physiologic responses were reproduced exactly in each simulation for all variables and interventions. Minor divergence was present between the time series generated with the METI HPS in the connected state but not in the disconnected state. The METI HPS showed some variation between simulations in the raw data. This was most usefully quantified using median absolute performance error as an indicator and was substantially reduced by preprocessing, particularly with dynamic time warping.
CONCLUSIONS: The repeatability of the physiologic response of model-controlled simulators to simple standardized interventions can be evaluated by considering divergence over time and the median absolute performance error of individual or pooled variables, but data should be preprocessed to eliminate irrelevant phase and frequency offsets in some variables. Dynamic time warping is an effective method for this purpose.

Entities:  

Year:  2015        PMID: 26335561     DOI: 10.1097/SIH.0000000000000098

Source DB:  PubMed          Journal:  Simul Healthc        ISSN: 1559-2332            Impact factor:   1.929


  3 in total

1.  Unlike History, Should a Simulator Not Repeat Itself?

Authors:  Samsun Lampotang
Journal:  Simul Healthc       Date:  2015-12       Impact factor: 1.929

2.  Participant perceptions of virtual simulation to develop non-technical skills in health professionals.

Authors:  Monica Peddle
Journal:  J Res Nurs       Date:  2019-06-08

3.  Arterial blood gas changes during cardiac arrest and cardiopulmonary resuscitation combined with passive oxygenation/ventilation: a METI HPS study.

Authors:  Matej Strnad; Damjan Lešnik; Miljenko Križmarić
Journal:  J Int Med Res       Date:  2018-09-05       Impact factor: 1.671

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.