A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

Fulai Peng1, Hongyun Liu, Weidong Wang.   

Abstract

A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the present study we present a comb filter based signal processing method. Firstly, wavelet de-noising was implemented to preliminarily suppress a part of the MAs. Then, the PPG signal in the time domain was transformed into the frequency domain by a fast Fourier transform (FFT). Thirdly, the PPG signal period was estimated from the frequency domain by tracking the fundamental frequency peak of the PPG signal. Lastly, the MAs were removed by the comb filter which was designed based on the obtained PPG signal period. Experiments with synthetic and real-world datasets were implemented to validate the performance of the method. Results show that the proposed method can effectively restore the PPG signals from the MA corrupted signals. Also, the accuracy of blood oxygen saturation (SpO2), calculated from red and infrared PPG signals, was significantly improved after the MA reduction by the proposed method. Our study demonstrates that the comb filter can effectively reduce the MAs from a PPG signal provided that the PPG signal period is obtained.

Entities:  

Mesh:

Year:  2015        PMID: 26334000     DOI: 10.1088/0967-3334/36/10/2159

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  Characterization of Quadratic Nonlinearity between Motion Artifact and Acceleration Data and its Application to Heartbeat Rate Estimation.

Authors:  Sunho Kim; Sungbin Im; Taehyung Park
Journal:  Sensors (Basel)       Date:  2017-08-14       Impact factor: 3.576

2.  A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China.

Authors:  Yongbo Liang; Zhencheng Chen; Guiyong Liu; Mohamed Elgendi
Journal:  Sci Data       Date:  2018-02-27       Impact factor: 6.444

3.  An optimal filter for short photoplethysmogram signals.

Authors:  Yongbo Liang; Mohamed Elgendi; Zhencheng Chen; Rabab Ward
Journal:  Sci Data       Date:  2018-05-01       Impact factor: 6.444

  3 in total