Literature DB >> 26332762

A resorbable antibiotic eluting bone void filler for periprosthetic joint infection prevention.

Zachary Jones1, Amanda E Brooks1,2, Zachary Ferrell1, David W Grainger1,3, Kristofer D Sinclair4.   

Abstract

Periprosthetic joint infection (PJI) following total knee arthroplasty is a globally increasing procedural complication. These infections are difficult to treat and typically require revision surgery. Antibiotic-loaded bone cement is frequently utilized to deliver antibiotics to the site of infection; however, bone cement is a nondegrading foreign body and known to leach its antibiotic load, after an initial burst release, at subtherapeutic concentrations for months. This work characterized a resorbable, antibiotic-eluting bone void filler designed to restore bone volume and prevent PJI. Three device formulations were fabricated, consisting of different combinations of synthetic inorganic bone graft material, degradable polymer matrices, salt porogens, and antibiotic tobramycin. These formulations were examined to determine the antibiotic's elution kinetics and bactericidal potential, the device's degradation in vitro, as well as osteoconductivity and device resorption in vivo using a pilot rabbit bone implant model. Kirby-Bauer antibiotic susceptibility tests assessed bactericidal activity. Liquid chromatography with tandem mass spectrometry measured antibiotic elution kinetics, and scanning electron microscopy was used to qualitatively assess degradation. Results indicated sustained antibiotic release from all three formulations above the Staphylococcus aureus minimum inhibitory concentration for a period of 5 to 8 weeks. Extensive degradation was observed with the Group 3 formulation after 90 days in phosphate-buffered saline, with a lesser degree of degradation observed in the other two formulations. Results from the pilot rabbit study showed the Group 3 device to be biocompatible, with minimal inflammatory response and no fibrous encapsulation in bone. The device was also highly osteoconductive-exhibiting an accelerated mineral apposition rate.
© 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1632-1642, 2016. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  controlled drug release; osteomyelitis; preclinical rabbit animal model; tobramycin; total joint revision

Mesh:

Substances:

Year:  2015        PMID: 26332762     DOI: 10.1002/jbm.b.33513

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  4 in total

1.  A Pre-clinical Standard Operating Procedure for Evaluating Orthobiologics in an In Vivo Rat Spinal Fusion Model.

Authors:  Andrew L Alejo; Scott McDermott; Yusuf Khalil; Hope C Ball; Gabrielle T Robinson; Ernesto Solorzano; Amanda M Alejo; Jacob Douglas; Trinity K Samson; Jesse W Young; Fayez F Safadi
Journal:  J Orthop Sports Med       Date:  2022-09-05

Review 2.  Recent advances in the local antibiotics delivery systems for management of osteomyelitis.

Authors:  Reem Khaled Wassif; Maha Elkayal; Rehab Nabil Shamma; Seham A Elkheshen
Journal:  Drug Deliv       Date:  2021-12       Impact factor: 6.819

Review 3.  Surgical Applications of Materials Engineered with Antimicrobial Properties.

Authors:  David P Perrault; Ayushi Sharma; Jessica F Kim; Geoffrey C Gurtner; Derrick C Wan
Journal:  Bioengineering (Basel)       Date:  2022-03-26

4.  Fabrication of Gentamicin-Loaded Hydroxyapatite/Collagen Bone-Like Nanocomposite for Anti-Infection Bone Void Fillers.

Authors:  Sho Oshima; Taira Sato; Michiyo Honda; Yasushi Suetsugu; Kazuhide Ozeki; Masanori Kikuchi
Journal:  Int J Mol Sci       Date:  2020-01-15       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.